background image

 

7

 

PROBLEM

POSSIBLE CAUSE

SOLUTION

The red BAD 

BATTERY 

 LED 

is lit.

The battery voltage is still below 

10V after 2 hours of charging.

(or)

In maintain mode, the output 

current is more than 1.5A for  

12 hours.

The battery is sulfated.

Lack of progress is detected and 

battery voltage is below 14.2V. 

 

The battery’s initial voltage is 

below 12.2V and the total input is 

less than 1.5 Ah.

The battery voltage drops to 

below 12.2V in Maintain Mode.

The battery may be defective. Make 

sure there are no loads on the battery. 

If there are, remove them. If there are 

none, have the battery checked or 

replaced.

The charger is in desulfation mode.

Continue charging for several hours. 

If not successful, have the battery 

checked.

The battery may be overheated. If 

so, allow the battery to cool. The 

battery may be too large or have a 

short circuit. Have battery checked 

or replaced.

The battery capacity is too low, or the 

battery is too old. Have it checked or 

replaced.

The battery won’t hold a charge. 

May be caused by a drain on the 

battery or the battery could be bad. 

Make sure there are no loads on the 

battery. If there are remove them. 

If there are none, have the battery 

checked or replaced.

14. SPECIFICATIONS

Input Voltage ..................................................................................120V AC @ 60Hz, 2.5A
Output Voltage ..............................................................................................................12V
Output Current Rating ...........................................................................10A DC @ 12V DC

15. BEFORE RETURNING FOR REPAIRS

If these solutions do not eliminate the problem,  

or for more information about troubleshooting,  

contact customer service for assistance:

[email protected]  

www.batterychargers.com

or call 1-800-621-5485

For 

REPAIR OR RETURN

, contact Customer Service at 1-800-621-5485. 

DO NOT SHIP 

UNIT

 until you receive a 

RETURN MERCHANDISE AUTHORIZATION (RMA) 

number 

from Customer Service at Schumacher Electric Corporation.

Summary of Contents for DSR PROSERIES DSR117

Page 1: ...ollow these instructions and precautions carefully POR FAVOR CONSERVE ESTE MANUAL DEL USUARIO Y LEALO ANTES DE CADA USO En este manual le explica c mo utilizar el cargador de bater a de manera segura...

Page 2: ...PLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT YOU FOLLOW THE INSTRUCTIONS EACH TIME YOU USE THE CHARGER b To reduce risk of battery explosion follow the...

Page 3: ...position and removing AC cord from electric outlet Never allow clips to touch each other 5 2 Attach clips to battery and chassis as indicated in Sections 6 and 7 6 FOLLOW THESE STEPS WHEN BATTERY IS I...

Page 4: ...per connection can result in a risk of an electric shock or electrocution NOTE Pursuant to Canadian Regulations use of an adapter plug is not allowed in Canada Use of an adapter plug in the United Sta...

Page 5: ...t use for industrial applications POWER UP IDLE TIME LIMIT If the Start Stop button is not pressed within 10 minutes after the battery charger is first powered up charging will automatically begin whe...

Page 6: ...INTENANCE AND CARE A minimal amount of care can keep your battery charger working properly for years Clean the clamps each time you are finished charging Wipe off any battery fluid that may have come...

Page 7: ...o cool The battery may be too large or have a short circuit Have battery checked or replaced The battery capacity is too low or the battery is too old Have it checked or replaced The battery won t hol...

Page 8: ...g repaired or modified by anyone other than Manufacturer or if this unit is resold through an unauthorized retailer Manufacturer makes no other warranties including but not limited to express implied...

Page 9: ...o o limpieza El simple apagado de los controles no reducir este riesgo 1 11 ADVERTENCIA RIESGO DE GASES EXPLOSIVOS a RESULTA PELIGROSO TRABAJAR EN FORMA CERCANAA UNA BATER A DE PLOMO LAS BATER AS GENE...

Page 10: ...salida se encuentre establecido en la tensi n correcta en su caso Si el cargador posee un ndice de carga ajustable cargue la bater a en el menor ndice en primer lugar 4 UBICACI N DEL CARGADOR 4 1 Ubi...

Page 11: ...a a la mayor distancia posible de la bater a Luego conecte el gancho NEGATIVO NEGRO del cargador al extremo libre del cable 7 5 No se ubique en posici n frontal a la bater a al realizar la conexi n fi...

Page 12: ...de CA o puede resultar en da os al cargador CARGA DE LA BATER A EN EL VEH CULO 1 Apague todos los accesorios del veh culo 2 Mantenga el cofre abierto 3 Limpie las terminales de la bater a 4 Coloque el...

Page 13: ...ja se encender FINALIZACI N DE LA CARGA La finalizaci n de la carga se indica con el LED CHARGED MAINTAINING verde Cuando est s lido el cargador ha pasado de modo de funci n a mantenimiento MODO DE MA...

Page 14: ...e ilumina El voltaje de la bater a todav a est debajo de 10V despu s de 2 horas de carga o En el modo de mantenimiento la corriente de salida es de m s de 1 5 A durante 12 horas La bater a est sulfata...

Page 15: ...sta garant a por lo accesorios utilizados con este producto que no sean los fabricados por Schumacher Electric Corporation y que no est n aprobados para su uso con este producto La presente Garant a L...

Page 16: ...IFS a IL EST DANGEREUX DE TRAVAILLER A PROXIMIT D UNE BATTERIE AU PLOMB LES BATTERIES PRODUISENT DES GAZ EXPLOSIFS EN SERVICE NORMAL IL EST AUSSI IMPORTANT DE TOUJOURS RELIRE LES INSTRUCTIONS AVANT D...

Page 17: ...EUR 4 1 Placez le chargeur aussi loin que possible de la batterie que les c bles CC le permettent 4 2 Ne jamais placer le chargeur directement sous la batterie charger les gaz ou les fluides qui s cha...

Page 18: ...raccordement 7 6 Pour interrompre l alimentation du chargeur mettre les interrupteurs hors circuit retirer le cordon C A de la prise enlever la pince raccord e au ch ssis et en dernier lieu celle racc...

Page 19: ...le capot ouvert 3 Nettoyez les bornes de la batterie 4 Placez le chargeur sur une surface s che et non inflammable 5 Posez les c bles CA CC l cart de toute pales de ventilateur courroies poulies et au...

Page 20: ...llume FIN DE CHARGE Ach vement de charge est indiqu par l op ration de CHARGED MAINTAINING vert LED Quand il est allum le chargeur est pass en mode de maintien de l op ration MODE DE MAINTIEN SURVEILL...

Page 21: ...at La charge ne progresse pas et la tension de la batterie est inf rieure 14 2 V La tension initiale de la batterie est inf rieure 12 2 V et le courant d entr e total est inf rieur 1 5 Ah La tension d...

Page 22: ...concernant les accessoires utilis s avec ce produit qui ne sont pas fabriqu s par Schumacher Electric Corporation et approuv s pour une utilisation avec ce produit Cette garantie limit e est annul si...

Page 23: ...ore Location_____________________ UPC Number_________________________ Serial Number_______________________________________ SEE PRODUCT For faster warranty activation go to www batterychargers com to r...

Page 24: ...r Electric Corporation 801 Business Center Drive Mount Prospect IL 60056 2179 U Nom________________________________________________________________ Adresse_____________________________________________...

Reviews: