GBA B 0705 0 E
BA
Page 21 of 24
November 17, 2015
Last revised 11-2015
Rev. 0
Scho
ll Ap
parat
eb
au
G
mb
H &
C
o
.
KG
8.4 E
XCHANGE OF THE
IRK-
HALOGEN
-
INFRARED
-
QUARTZ RADIATOR
Maintenance and repairs on the appliance must only be carried out by an author-
ized professional observing applicable safety regulations.
Improperly executed work will put your safety at risk!
Before any cleaning, maintenance or repair work is carried out, the appliance must
be disconnected from the mains and de-energized. To do so, it is not enough to set
the power switch to OFF. Instead, the mains plug must be pulled or the electrical
circuit must be de-energized, respectively. Check that no voltage is present before
opening the appliance, and lock out the circuit to make it safe against re-energizing.
Always
follow the written instructions that come with the replacement part IRK-
halogen-infrared-quartz radiator!
Do
not
touch the IRK-halogen-infrared-quartz radiator with bare hands!
Loosen the two screws at the bottom of the casing to replace the IRK-halogen-infrared-quartz radiator.
Then remove the lower casing parts and the protective grille. Push the defective IRK-halogen-infrared-
quartz radiator in the socket a little bit aside and then remove it.
Insert the new IRK-halogen-infrared-quartz radiator. Thereafter screw the lower side casing part with pro-
tection grille.