Caution

Safety precaution

Caution

Caution before use.

・ Location which will be gotten water
・ Locations which receive direct sunlight
・ Dew condensation place

Do not use AC plug covered with dust.

Do  not  use  and  keep  the  FGJN  under 
the following circumstances.

Please  use  the  FGJN  in  operating 

temperature in range 0℃~40℃ .

It might the cause of the fire.

When  the  FGJN  is  dirty,  please  wipe  with  dry  soft 
cloth,  or  please  give  the  cloth  soak  in  detergent 
which has mixed with water, then wring the cloth and 
wipe with it.  Do not use a volatile chemical such as 

benzene, thinner, and alcohol.

If  you  use  FGP  beyond  above  temperature,  FGP 
might operate unusual.

1. Do not press the button with 
   a sharp-pointed object.

2. Do not load bending direction or twisting direction.

PEAK

ZERO

MEM

UNIT

PEAK

ZERO

MEM

UNIT

PEAK

ZERO

MEM

UNIT

FGP can measure pulling load and compression load.  Do not load bending 
direction or twisting direction. Though FGJN has a stopper which protects 
the sensor from careless operation, this stopper is helplessness for impact 
load, bending direction, and twisting direction.

Bending direction

Twisting direction

We  recommend  the  force  gauge  to  be  checked 
and  calibrated  regularly.    Though  it  is  depend  on 
the  frequency  of  use  and  loading,  the  accuracy  of 
measurement will be declined with time.

3. Do not fall the force gauge.

Do not fall the force gauge 
into  the  ground.    Sensor 
m i g h t   b e   b r o k e n   a n d 
you  cannot  get  accurate 
measurement value.

PEAK

ZERO

MEM

UNIT

4. Do not use the force gauge in location which will be gotten water.

This  force  gauge  is  not  water 
proof.    Please  do  not  operate 
the  force  gauge  in  location 
which will be gotten water.

PEAK

ZERO

MEM

UNIT

5. Measuring very small loading

Tracking  is  ON  at  the  factory 
default.    When  you  measure 
small  load,  please  turn  the 

tracking OFF. ( ⇒ Please refer 

4.4. Tracking)

PEAK

ZERO

MEM

UNIT

Please operate the force gauge within 

operating humidity range; 35 ~ 85RH.

If you use the force gauge beyond the above range, 
it might produce improper operation.

・ Dusty, salinity and iron content environments
・ Location which will be gotten oil and chemical
・ Corrosive and Flammable gas environment

Overload

Summary of Contents for FG Series

Page 1: ...Force Gauge FG Series Model FGJN Edition FGJN 01 E Operating Instructions Valid as of 01 10 2015 Please keep the manual for future reference S C H M I D T c o n t r o l i n s t r u m e n t s ...

Page 2: ...ution Warning Caution Safety Precaution When you use FGJN wrongly it may cause serious problem such as death or severe injury When you use FGJN wrongly it might cause serious problem depend on the situation Please be careful to the flying apart of the test substance Do not use scarred hook or deformed hook At the breakdown test or break test you might get injury due to the flying apart of the obje...

Page 3: ... careless operation this stopper is helplessness for impact load bending direction and twisting direction Bending direction Twisting direction We recommend the force gauge to be checked and calibrated regularly Though it is depend on the frequency of use and loading the accuracy of measurement will be declined with time 3 Do not fall the force gauge Do not fall the force gauge into the ground Sens...

Page 4: ...1 Sign f01 9 4 5 2 Display update time f02 9 4 5 3 Auto power off f03 9 4 5 4 Function mode end 10 4 6 Reverse the display 10 5 Feature and Operation 10 5 1 Overview of operation 10 5 2 Measuring mode 11 5 2 1Standard measuring mode 11 5 2 2Peak hold mode 11 5 3 Change display unit 11 5 4 Tare 11 5 5 Overload 11 6 Frequently asked questions 12 6 1 Questions for trouble 12 6 2 Questions for technic...

Page 5: ...mber 1 Product Features デジタル フォースゲージ FGP 0 2 0 5 1 2 5 10 20 50 100 Nickel hydrogen battery enable us to use long time 4 1 Charge Rated Capacity 2 000N 200 0gf 8oz 500N 50 0kgf 100lb 8 Specifications and Dimensions Reverse the display of the measuring value and the unit 4 6 Reverse the display One touch shimple operation for changing the unit N kg g Lb oz 5 3 Change display unit Measure peak value...

Page 6: ...he ZERO key under the peak hold mode display the peak value clear the peak value In this case tare does not perform If you need tare press the peak key to change into standard measuring mode then press the Zero key POWER key Press the POWER and release to turn ON OFF It is used for reverse the display Tracking ON OFF It is used for function setting AC adapter port Supply the electricity through th...

Page 7: ...Peak hold mode display In case of the voltage of internal nickel hydride battery decrease LO BAT has turned on and off Please connect AC adapter to charge the battery D u r i n g t h e c h a r g e of battery BAT is shown Even if turn the power off during the charge BAT has displayed PEAK has turned on when plus peak hold mode PEAK has turned on when minus peak hold mode Newton Depend on the condit...

Page 8: ...display while charging After complete the charging BAT will be disappeared from LCD Charge time Up to 16 hours at most Operating time Approx 8 hours per 1 full charge The nickel hydride battery is charged automatically when it is discharged during the usage of AC adapter If you charge the battery frequently its lifetime will be shorten When you use the FGJN with AC adapter you should not insert an...

Page 9: ...ch the tracking ON OFF Display force gauge model J Tracking OFF Tracking ON Standard measuring mode Please release the PEAK key and UNIT key after the value is appeared in the display more than 1 second Tracking ON Tracking OFF 4 5 Function setting Key operation Display Turn the power off Hold down ZERO key Press POWER key Release POWER key only Display force gauge model Display function mode f01 ...

Page 10: ...e Press the UNIT key to choose the display update time 1 2 3 5 10 20 times second Press the PEAK key to move ahead 1 time sec 2 times sec 3 times sec 5 times sec 10 times sec 20 times sec Key operation Display Each time to press UNIT Register the all setting and then move to the standard measuring mode Reserve the change and then move to f04 4 5 3 Auto power off f03 If the gauge is on and there is...

Page 11: ...ing mode Reverse display Reverse disply Standard display Key Operation POWER Turn the POWER ON OFF ZERO Tare Peak reset at the PEAK Hold mode PEAK Standard measuring mode Plus peak hold mode Minus peak hold mode UNIT Change the unit Key Operation How to operate PEAK UNIT POWER Tracking ON OFF Turn POWER off Press PEAK key and UNIT key simultaneously and hold then press and release POWER key releas...

Page 12: ...rom maximum pulling load to maximum compression load When measuring range is over OVR is displayed Press the ZERO key under the plus peak hold mode or minus peak hold mode plus peak value or minus peak value is cleared At the plus peak hold mode and minus peak hold mode tare does not performed even if press and release ZERO key When turning POWER on tare is automatically performed if you turn POWE...

Page 13: ...e Although I downloaded Toriemon it doesn t work even if connecting force gauge Since Toriemon is soft forRS 232C transmission it doesn t respond to USB transmission Please download ToriemonUSB and use it Questions Explanation Reference How long does rechargeable battery Nickel hydride battery last Enable to use 500 times or more by complete electric discharge It depends on the status of use Pleas...

Page 14: ...b Reversible display Mesuring mode Standard measuring Plus peak measuring Minus peak measuring Display cycle 1 2 3 5 10 20 times per second Sampling rate 1000 times per second Accuracy 0 3 R C 1 2digit 23 Influence of temparature Gain 0 03 LOAD Zero 0 02 R C Drift of zero point can be cancelled with tracking function Display Main display 4 digits 12mm high Reversible display Unit display 3 digits ...

Page 15: ...nts standard accessories Flat head φ 12 Chisel 70 Hook Notched head 70 Cone head 70 Extension rod L 92 8 Specifications and Dimensions Dimensions M6 φ10 26 70 3 5 M6 8 43 φ10 R 4 M6 26 φ10 70 M6 φ10 26 70 M6 M6 φ10 φ6 12 92 80 14 ...

Page 16: ...Thickness Gauge Yarn Package Durometer and Shore A Durometer Sample Cutter Balance Moisture Meter Leak Tester Softometer Mailing address P O B 1154 84464 Waldkraiburg Germany Shipping address Schichtstr 16 84478 Waldkraiburg Germany Hans Schmidt Co GmbH Phone int 49 0 8638 9410 0 Fax int 49 0 8638 4825 int 49 0 8638 67898 More than 60 years Worldwide e mail info hans schmidt com Internet http www ...

Reviews: