background image

-11-

-12-

  6.Frequently –asked questions

  6.2.Questions for technical

  6.1.Questions for trouble

Questions

Cause

Presumable reason

Procedure

When turning on power, “OVR” is
displayed even if not applying load
and cannot be cleared by pushing
ZERO key. 

There is possibility which
internal loadsell is broken.

Due to dropment or
 overloading

Please send it for repair.

“Low bat” is displayed at LCD even
if charging up for more than one day.

Voltage of battery is low.

・ End of battery life

Please send it fot repair.

・ Breakdown of battery
・ Breakdown of charging 

It doesn't display even if pressing
POWER Key.

Battery is weak.

Voltage of battery is lower.

Please charge a battery.

“BAT” isn't displayed on 

LCD even if charging up.

・ Breakdown of battery

Please send it for repair.

・ Breakdown of internal

  circuit

・ Breakdown of AC adapter

The value becomes “0”automatically 
when measuring small value near 0.

You can use tracking to

prevent the fluctuation of the

measuring value near “0” . 

Tracking is on.

Please set tracking off.

(Refer to “4.4.Tracking”)

Value changes if you change the
direction of force gauge.

This is not breakdown.
This equipment is measuring
the empty weight of sensor
on his own.

Sensor or tools also have
weight empty operating.

Push ZERO key after setting

the direction to measure and
clear the measuring value.

Although I downloaded “Toriemon” ,
it doesn't work even if connecting
force gauge.

-

Since “Toriemon” is soft
forRS-232C transmission,
it doesn't respond to USB
transmission.

Please download
“ToriemonUSB” and use it.

 

 

Questions

 Explanation

Reference

How long does rechargeable battery

(Nickel hydride battery) last?

Enable to use 500 times or more by
complete electric discharge. It depends on
the status of use.

Please charge battery after discharging

electricity until “LO BAT” is displayed at

LCD. 

Why are there various rating

capacity?

The value is more accurate when measuring
near rating as much as possible.

It is ideal to use this equipment with 50%
rating or more.

Why does measuring data show

variations?

Although there are many reasons, the
measuring value is affected by vibration if
you hold by hands.

Fluctuation will be reduced when using
stand.

How  does  biased  loading  affect 

accurancy?

Although it depends on the angle, you
cannot measure accurate value with biased
loading. 

How do you proceed ISO cariblation 

?

It measures the value by pushing or pulling

load by certificated weight.

Weight with traceability is necessary. 

Please tell easy test methods which 
user can.

Please hang the weihgt which weight is
clear.

Can user exchange battery?

User cannot exchange battery.

Please let our dealers know since exchange
of battery is as repairment.

Do you have CAD data ?

Yes.

Please let our dealers know.

Is it possible to use in water ?

No. It is not waterproof structure.

Please pay attention not to pour water.

-11-

-12-

It’ s avairable to measure the compression and tension force. Measuring value is appeared at all times.

1) Press POWER key and release ( Turn POWER on after release)
2) Press ZERO key to tare.
Displayed measuring value is averaged out the sampling value (every 1 msec * ) per display update time.
Display  update  time  of  default  factory  setting  is  3  times/second.  In  order  to  increase  the  display  response  against  the  change  of  measuring 

value, you may change the set value of display update time.

You can increase this time up to 20 times/second (regarding the change of display update time, please refer “4.5.2. Display update time” .) 

To change the display units, just press UNIT and the units will change every time the button is pressed.

N→ kg (g) → lb (oz) → N 

”OVR” shows on the LCD when the load exceed 120% of the capacity (tare value is not included ).

Please reduce the load  immediately.

Press ZERO key to reset the measuring value. Please press the ZERO key before starting the measurement in order not to change the starting 

display value because of the own weight or measuring direction or weight of measuring fixture.

Measuring range is from maximum pulling load to maximum compression load.  When measuring range is over, “OVR” is displayed.

Press the ZERO key under the plus peak hold mode or minus peak hold mode, plus peak value or minus peak value is cleared.  At the plus peak 

hold mode and minus peak hold mode, tare does not performed even if press and release ZERO key.

When turning POWER on, tare is automatically performed (if you turn POWER on during the getting load, display becomes “0” and you cannot 

measure accurate value).

  5.2.1Standard measuring mode

  5.3.Change display unit

  5.4.Tare

  5.5.Overload

  5.2.2 Peak hold mode

Display peak measuring value. Sampling time is 1ms. *
Press PEAK key to change standard measuring mode, Plus peak hold mode and Minus peak hold mode.
Under the plus peak hold mode, “PEAK” is appeared.
Under the minus peak hold mode, “PEAK” and “- “ (minus) are appeared.

Key operation

Display

Each time to press PEAK

Standard measuring mode

Plus peak hold mode

Minus peak hold mode

Under the plus peak hold mode and minus peak hold mode, press ZERO key to clear the peak value (Tare is not performed).

  5.2.Measuring Mode

There are standard measuring mode and peak hold mode in the measuring mode.

Key operation

Display

Press and release

Display force gauge model

Standard measuring mode

Display tracking ON/OFF

PEAK

ZERO

UNIT

POWER

PEAK

ZERO

UNIT

POWER

J

OVR

Summary of Contents for FG Series

Page 1: ...Force Gauge FG Series Model FGJN Edition FGJN 01 E Operating Instructions Valid as of 01 10 2015 Please keep the manual for future reference S C H M I D T c o n t r o l i n s t r u m e n t s ...

Page 2: ...ution Warning Caution Safety Precaution When you use FGJN wrongly it may cause serious problem such as death or severe injury When you use FGJN wrongly it might cause serious problem depend on the situation Please be careful to the flying apart of the test substance Do not use scarred hook or deformed hook At the breakdown test or break test you might get injury due to the flying apart of the obje...

Page 3: ... careless operation this stopper is helplessness for impact load bending direction and twisting direction Bending direction Twisting direction We recommend the force gauge to be checked and calibrated regularly Though it is depend on the frequency of use and loading the accuracy of measurement will be declined with time 3 Do not fall the force gauge Do not fall the force gauge into the ground Sens...

Page 4: ...1 Sign f01 9 4 5 2 Display update time f02 9 4 5 3 Auto power off f03 9 4 5 4 Function mode end 10 4 6 Reverse the display 10 5 Feature and Operation 10 5 1 Overview of operation 10 5 2 Measuring mode 11 5 2 1Standard measuring mode 11 5 2 2Peak hold mode 11 5 3 Change display unit 11 5 4 Tare 11 5 5 Overload 11 6 Frequently asked questions 12 6 1 Questions for trouble 12 6 2 Questions for technic...

Page 5: ...mber 1 Product Features デジタル フォースゲージ FGP 0 2 0 5 1 2 5 10 20 50 100 Nickel hydrogen battery enable us to use long time 4 1 Charge Rated Capacity 2 000N 200 0gf 8oz 500N 50 0kgf 100lb 8 Specifications and Dimensions Reverse the display of the measuring value and the unit 4 6 Reverse the display One touch shimple operation for changing the unit N kg g Lb oz 5 3 Change display unit Measure peak value...

Page 6: ...he ZERO key under the peak hold mode display the peak value clear the peak value In this case tare does not perform If you need tare press the peak key to change into standard measuring mode then press the Zero key POWER key Press the POWER and release to turn ON OFF It is used for reverse the display Tracking ON OFF It is used for function setting AC adapter port Supply the electricity through th...

Page 7: ...Peak hold mode display In case of the voltage of internal nickel hydride battery decrease LO BAT has turned on and off Please connect AC adapter to charge the battery D u r i n g t h e c h a r g e of battery BAT is shown Even if turn the power off during the charge BAT has displayed PEAK has turned on when plus peak hold mode PEAK has turned on when minus peak hold mode Newton Depend on the condit...

Page 8: ...display while charging After complete the charging BAT will be disappeared from LCD Charge time Up to 16 hours at most Operating time Approx 8 hours per 1 full charge The nickel hydride battery is charged automatically when it is discharged during the usage of AC adapter If you charge the battery frequently its lifetime will be shorten When you use the FGJN with AC adapter you should not insert an...

Page 9: ...ch the tracking ON OFF Display force gauge model J Tracking OFF Tracking ON Standard measuring mode Please release the PEAK key and UNIT key after the value is appeared in the display more than 1 second Tracking ON Tracking OFF 4 5 Function setting Key operation Display Turn the power off Hold down ZERO key Press POWER key Release POWER key only Display force gauge model Display function mode f01 ...

Page 10: ...e Press the UNIT key to choose the display update time 1 2 3 5 10 20 times second Press the PEAK key to move ahead 1 time sec 2 times sec 3 times sec 5 times sec 10 times sec 20 times sec Key operation Display Each time to press UNIT Register the all setting and then move to the standard measuring mode Reserve the change and then move to f04 4 5 3 Auto power off f03 If the gauge is on and there is...

Page 11: ...ing mode Reverse display Reverse disply Standard display Key Operation POWER Turn the POWER ON OFF ZERO Tare Peak reset at the PEAK Hold mode PEAK Standard measuring mode Plus peak hold mode Minus peak hold mode UNIT Change the unit Key Operation How to operate PEAK UNIT POWER Tracking ON OFF Turn POWER off Press PEAK key and UNIT key simultaneously and hold then press and release POWER key releas...

Page 12: ...rom maximum pulling load to maximum compression load When measuring range is over OVR is displayed Press the ZERO key under the plus peak hold mode or minus peak hold mode plus peak value or minus peak value is cleared At the plus peak hold mode and minus peak hold mode tare does not performed even if press and release ZERO key When turning POWER on tare is automatically performed if you turn POWE...

Page 13: ...e Although I downloaded Toriemon it doesn t work even if connecting force gauge Since Toriemon is soft forRS 232C transmission it doesn t respond to USB transmission Please download ToriemonUSB and use it Questions Explanation Reference How long does rechargeable battery Nickel hydride battery last Enable to use 500 times or more by complete electric discharge It depends on the status of use Pleas...

Page 14: ...b Reversible display Mesuring mode Standard measuring Plus peak measuring Minus peak measuring Display cycle 1 2 3 5 10 20 times per second Sampling rate 1000 times per second Accuracy 0 3 R C 1 2digit 23 Influence of temparature Gain 0 03 LOAD Zero 0 02 R C Drift of zero point can be cancelled with tracking function Display Main display 4 digits 12mm high Reversible display Unit display 3 digits ...

Page 15: ...nts standard accessories Flat head φ 12 Chisel 70 Hook Notched head 70 Cone head 70 Extension rod L 92 8 Specifications and Dimensions Dimensions M6 φ10 26 70 3 5 M6 8 43 φ10 R 4 M6 26 φ10 70 M6 φ10 26 70 M6 M6 φ10 φ6 12 92 80 14 ...

Page 16: ...Thickness Gauge Yarn Package Durometer and Shore A Durometer Sample Cutter Balance Moisture Meter Leak Tester Softometer Mailing address P O B 1154 84464 Waldkraiburg Germany Shipping address Schichtstr 16 84478 Waldkraiburg Germany Hans Schmidt Co GmbH Phone int 49 0 8638 9410 0 Fax int 49 0 8638 4825 int 49 0 8638 67898 More than 60 years Worldwide e mail info hans schmidt com Internet http www ...

Reviews: