Key operation
Display
Turn the power off
① Hold down UNIT key
② Press POWER key.
Release POWER key only.
Press ZERO key to memorize the set value and come back from function mode to standard measuring mode.
In order to cancel the change of function mode, press POWER key, then turn the POWER off.
4.5.4.Function mode-end
PEAK
ZERO
UNIT
POWER
PEAK
ZERO
UNIT
POWER
In the case you attach FGJN with a stand, display of the value and the units can be reversed in order to read the display easily.
Turn POWER off. Press the UNIT key and hold, then press POWER key and release (release UNIT key after the value is appeared in the display
more than 1 second). Then you can reverse the disply.
4.6.Reverse the display
Please release the
UNIT key after the
value is appeared in
the display more than
1 second.
Display force gauge model
Standard display
Standard measuring mode
Reverse display
Reverse disply
Standard display
①
②
Key
Operation
POWER
Turn the POWER ON/OFF
ZERO
Tare (Peak reset at the PEAK Hold mode)
PEAK
Standard measuring mode / Plus peak hold mode / Minus peak hold mode
UNIT
Change the unit
Key
Operation
How to operate
PEAK + UNIT
POWER
Tracking
ON / OFF
Turn POWER off. Press PEAK key and UNIT key simultaneously and hold, then press and
release POWER key (release the PEAK key and UNIT key after the value is appeared in
the display more than 1 second.)
ZERO
POWER
Function mode
Turn POWER off. Press ZERO key and hold, then press POWER key and release (release
ZERO key after the value is appeared in the display more than 1 second).
Function mode;
UNIT : Change the setting content
PEAK : Switch the function
ZERO : Register the setting content
UNIT
POWER
Reverse display
Turn POWER off. Press UNIT key and hold, then press POWER key and release (release
the UNIT key after the value is appeard in the display more than 1 second.)
5.Feature and Operation
5.1.Overview of operation
1) Basic operation
2) Special operation
J
J
-9-
-10-
Key operation
Display
Each time to press UNIT
Register the all setting, and then move to the standard measuring mode.
Reserve the change, and then move to f03.
Key operation
Display
Each time to press UNIT
Register the all setting, and then move to the standard measuring mode.
Reserve the change, and then move to f02.
It’ s available to set the sign (plus or minus) of measuring value for pushing the sensor shaft.
Select the sign by use of UNIT key / Press the PEAK key to move ahead.
Minus
Plus
4.5.2.Display update time: f02
It’ s available to set the display update time for 1 time/second, 2 times/second, 3 times/second, 5 times/second, 10 times/second and 20
times/second. After the setting, the averaging value in display update time is shown every display update time.
Press the UNIT key to choose the display update time (1、 2、 3、 5、 10、 20 (times/second) ) / Press the PEAK key to move ahead
1 time/sec
2 times/sec
3 times/sec
5 times/sec
10 times/sec
20 times/sec
Key operation
Display
Each time to press UNIT
Register the all setting, and then move to the standard measuring mode.
Reserve the change, and then move to f04.
4.5.3.Auto power off: f03
If the gauge is on and there is no activity for 10 minutes*, the unit automatically powers off to conserve battery charge (In case of
connected with AC adapter, Auto power off function does not work). “PWR” appears to notify that there is 1 minute before power off.
Press the UNIT key to switch the auto power off / Press the PEAK key to move ahead
※ There is no key operation, RS-232C communication, USB communication, change of measuring value.
Auto power off, 10 min
Auto power off is not available.
4.5.1.Sign: f01
PEAK
ZERO
UNIT
POWER
PEAK
ZERO
UNIT
POWER
PEAK
ZERO
UNIT
POWER
PEAK
PEAK
PEAK
ZERO
ZERO
ZERO