Key operation

Display

Turn the power off

① Hold down PEAK and UNIT key,
② Press POWER key.

 Release POWER key only.

  4.4.Tracking

A load cell of strain gauge is used for FGJN as a load sensing. By using this sensor, the measuring value is slightly changed due to temperature 
and so on, but tracking is able to cancel this slightly change by the software. When you measure very minute forces, measuring value error 
might happen due to the tracking.  In this case, you may turn off the tracking function.

When the power off, while hold down the PEAK key and UNIT key simultaneously, press and release the POWER key (release the PEAK key and 
UNIT key after the value is appeard in the display more than 1 second), you can switch the tracking ON/OFF. 

Display force gauge model

J

Tracking OFF

Tracking ON

Standard measuring mode

Please release the PEAK 

key and UNIT key after 
the value is appeared in 
the display more than 1 
second.

Tracking ON

Tracking OFF

  4.5.Function setting

Key operation

Display

Turn the power off

 

① Hold down ZERO key,

 ②

Press POWER key.

              

  

Release POWER key only.

Display force gauge model

Display function mode (f01)

Please release the ZERO 

key  after  the  value  is 
appeared  in  the  display 
more than 1 second.

The following setting items in function mode.

Item

Unit

Set contents

Default factory setting

Display sign

f01

-0001(minus), 0001 (plus)

0001

Display update time

f02

1、 2、 3、 5、 10、 20 (times/second)

3

Auto power off

f03

10 (10 minutes )、 oFF (not valid)

10

Turn power off, then press POWER key, you can confirm the condition of 

the present tracking.

PEAK

ZERO

UNIT

POWER

PEAK

ZERO

UNIT

POWER

PEAK

ZERO

UNIT

POWER

PEAK

ZERO

UNIT

POWER

J

-7-

-8-

  4.2.Attaching measuring adapter

Please select the measuring adapter depend on the measuring purpose. 

Screw the adapter until it stops lightly. Do not screw it forcibly in order 

not to give the damage to the sensor.

Do not use bruised hook or 
deformed hook.

Flat head

Cone head

Notched head

Chisel

Extension rod

Hook

PEAK

ZERO

  4.Before use

  4.1.Charge

Do  not  charge  with  non-

attached AC adapter.

Please  use  AC  adapter  which  supplied  with  FGJN.  If  you  use  non-attached  AC 

adapter, electronic circuit might be broken and fire might happen.

Before the FGJN arrive at your hand, nickel hydride battery might discharge electricity.

Please plug attached AC adapter and charge before you use.

① Please connect the attached AC adapter into the 

AC adapter port

 of the

  body, and plug them into outlet.

・ Start to charge the Nickel hydride battery.  After the completion of the

  charge, it stops charging automatically by itself.

・ “BAT” will be shown on the LCD display while charging. After complete the

  charging, “BAT” will be disappeared from LCD.

・ Charge time: Up to 16 hours at most 

・ Operating time: Approx. 8 hours per 1 full charge 

② The nickel hydride battery is charged automatically when it

  is discharged during the usage of AC adapter.

※ If you charge the battery frequently, its lifetime will be shorten. 
  When you use the FGJN with AC adapter, you should not insert and
  remove the AC adapter often.

③ You can measure during the charge.

  4.3.Attaching hanger

Please  take  off  the  attached  hanger  bolt.    Fit  the 

square  hole  of  hanger  into  the  salient  part  of  the 

case, and then tighten the attached hanger bolt.

Please use the hunger to hang the FGJN with 

a nail or a winch.

※ Please use the tolerable nail or 

winch against the load .

④ When the voltage of nickel hydride battery decline, “LoBAT”

  has turned on in the LCD display.  Please connect the

  AC adapter to charge.  (If you leave the FGJN with turned

  on “LoBAT” , the voltage decline furthermore, and then the 

power

  is turned off compulsory.)

Hunger attachement bolt

Hunger

AC adapter port

Please attached the hunger according to need.

Do  not  screw  the  attachment 
in forcebly.

Summary of Contents for FG Series

Page 1: ...Force Gauge FG Series Model FGJN Edition FGJN 01 E Operating Instructions Valid as of 01 10 2015 Please keep the manual for future reference S C H M I D T c o n t r o l i n s t r u m e n t s ...

Page 2: ...ution Warning Caution Safety Precaution When you use FGJN wrongly it may cause serious problem such as death or severe injury When you use FGJN wrongly it might cause serious problem depend on the situation Please be careful to the flying apart of the test substance Do not use scarred hook or deformed hook At the breakdown test or break test you might get injury due to the flying apart of the obje...

Page 3: ... careless operation this stopper is helplessness for impact load bending direction and twisting direction Bending direction Twisting direction We recommend the force gauge to be checked and calibrated regularly Though it is depend on the frequency of use and loading the accuracy of measurement will be declined with time 3 Do not fall the force gauge Do not fall the force gauge into the ground Sens...

Page 4: ...1 Sign f01 9 4 5 2 Display update time f02 9 4 5 3 Auto power off f03 9 4 5 4 Function mode end 10 4 6 Reverse the display 10 5 Feature and Operation 10 5 1 Overview of operation 10 5 2 Measuring mode 11 5 2 1Standard measuring mode 11 5 2 2Peak hold mode 11 5 3 Change display unit 11 5 4 Tare 11 5 5 Overload 11 6 Frequently asked questions 12 6 1 Questions for trouble 12 6 2 Questions for technic...

Page 5: ...mber 1 Product Features デジタル フォースゲージ FGP 0 2 0 5 1 2 5 10 20 50 100 Nickel hydrogen battery enable us to use long time 4 1 Charge Rated Capacity 2 000N 200 0gf 8oz 500N 50 0kgf 100lb 8 Specifications and Dimensions Reverse the display of the measuring value and the unit 4 6 Reverse the display One touch shimple operation for changing the unit N kg g Lb oz 5 3 Change display unit Measure peak value...

Page 6: ...he ZERO key under the peak hold mode display the peak value clear the peak value In this case tare does not perform If you need tare press the peak key to change into standard measuring mode then press the Zero key POWER key Press the POWER and release to turn ON OFF It is used for reverse the display Tracking ON OFF It is used for function setting AC adapter port Supply the electricity through th...

Page 7: ...Peak hold mode display In case of the voltage of internal nickel hydride battery decrease LO BAT has turned on and off Please connect AC adapter to charge the battery D u r i n g t h e c h a r g e of battery BAT is shown Even if turn the power off during the charge BAT has displayed PEAK has turned on when plus peak hold mode PEAK has turned on when minus peak hold mode Newton Depend on the condit...

Page 8: ...display while charging After complete the charging BAT will be disappeared from LCD Charge time Up to 16 hours at most Operating time Approx 8 hours per 1 full charge The nickel hydride battery is charged automatically when it is discharged during the usage of AC adapter If you charge the battery frequently its lifetime will be shorten When you use the FGJN with AC adapter you should not insert an...

Page 9: ...ch the tracking ON OFF Display force gauge model J Tracking OFF Tracking ON Standard measuring mode Please release the PEAK key and UNIT key after the value is appeared in the display more than 1 second Tracking ON Tracking OFF 4 5 Function setting Key operation Display Turn the power off Hold down ZERO key Press POWER key Release POWER key only Display force gauge model Display function mode f01 ...

Page 10: ...e Press the UNIT key to choose the display update time 1 2 3 5 10 20 times second Press the PEAK key to move ahead 1 time sec 2 times sec 3 times sec 5 times sec 10 times sec 20 times sec Key operation Display Each time to press UNIT Register the all setting and then move to the standard measuring mode Reserve the change and then move to f04 4 5 3 Auto power off f03 If the gauge is on and there is...

Page 11: ...ing mode Reverse display Reverse disply Standard display Key Operation POWER Turn the POWER ON OFF ZERO Tare Peak reset at the PEAK Hold mode PEAK Standard measuring mode Plus peak hold mode Minus peak hold mode UNIT Change the unit Key Operation How to operate PEAK UNIT POWER Tracking ON OFF Turn POWER off Press PEAK key and UNIT key simultaneously and hold then press and release POWER key releas...

Page 12: ...rom maximum pulling load to maximum compression load When measuring range is over OVR is displayed Press the ZERO key under the plus peak hold mode or minus peak hold mode plus peak value or minus peak value is cleared At the plus peak hold mode and minus peak hold mode tare does not performed even if press and release ZERO key When turning POWER on tare is automatically performed if you turn POWE...

Page 13: ...e Although I downloaded Toriemon it doesn t work even if connecting force gauge Since Toriemon is soft forRS 232C transmission it doesn t respond to USB transmission Please download ToriemonUSB and use it Questions Explanation Reference How long does rechargeable battery Nickel hydride battery last Enable to use 500 times or more by complete electric discharge It depends on the status of use Pleas...

Page 14: ...b Reversible display Mesuring mode Standard measuring Plus peak measuring Minus peak measuring Display cycle 1 2 3 5 10 20 times per second Sampling rate 1000 times per second Accuracy 0 3 R C 1 2digit 23 Influence of temparature Gain 0 03 LOAD Zero 0 02 R C Drift of zero point can be cancelled with tracking function Display Main display 4 digits 12mm high Reversible display Unit display 3 digits ...

Page 15: ...nts standard accessories Flat head φ 12 Chisel 70 Hook Notched head 70 Cone head 70 Extension rod L 92 8 Specifications and Dimensions Dimensions M6 φ10 26 70 3 5 M6 8 43 φ10 R 4 M6 26 φ10 70 M6 φ10 26 70 M6 M6 φ10 φ6 12 92 80 14 ...

Page 16: ...Thickness Gauge Yarn Package Durometer and Shore A Durometer Sample Cutter Balance Moisture Meter Leak Tester Softometer Mailing address P O B 1154 84464 Waldkraiburg Germany Shipping address Schichtstr 16 84478 Waldkraiburg Germany Hans Schmidt Co GmbH Phone int 49 0 8638 9410 0 Fax int 49 0 8638 4825 int 49 0 8638 67898 More than 60 years Worldwide e mail info hans schmidt com Internet http www ...