background image

Operating Manual 

V

ACU

M

ASTER

 Multi-Serie 

Chapter 1 

Safety

 

J. Schmalz GmbH 
Aacher Straße  29 
D  - 72293 Glatten 
Tel  +49 +7443 / 2403 - 0 
Fax +49 +7443 / 2403 - 259 
http://www.schmalz.de 
e-mail: [email protected] 

 

 

BA 30.30.01.00221-00 

Status 03.2013 

Page 5/18 

 

1.5  Intended Use 

 
 
 
 

 

Lifting devices series 

V

ACU

M

ASTER 

M

ULTI

 are designed to lift and transport flat 

and slightly bent boards of various materials, e.g. wood, particle board,  
sheet-metal or plastic boards. The boards may have porous surfaces. 
When using lifting devices with a single suction box the load have to be flat. 
 

 

Caution

 

 

The maximum lifting capacity must not be exceeded. 

Observe the name plate. 

 

Danger

 

 

Transport of persons and animals with the load or the lifting device 
itself is forbidden! 

 

Unauthorized alteration of the lifting device is forbidden for safety 
reasons! 

 

The operating, maintenance and service instructions in this manual 

must be observed.

 

 

 

 

1.6  Emissions 

The equivalent continuous sound pressure level of the lifting device is  
below 75 dB(A). 

 

1.7  Special Hazards 

 

 

Danger

 

Since the load is retained by a vacuum it will fall off as soon as this  
vacuum is lost. 
This happens in a sudden power failure. An alarm signal switches on. 
When power fails immediately put the load down if possible. If this is not 
possible, immediately leave the dangerous area near the load 

 

Danger

 

The device generates a very strong suction which can draw in hair and 
clothing. Do not look into the suction opening when the device is 
switched on. Parts of body can be sucked in. 
 

 

 

 

1.8  Workplaces 

The workplace of the operator is in front of the control handle. Stand in a 
position that allows you to keep a constant eye on the vacuum pressure gauge. 
 

1.9  Instructions for the 

Operator 

As an operator of the lifting device you must be trained before start-up.  
You must have read and understood the operating instructions and especially 
the chapter "Safety". 
Be sure, that only authorized persons use the device. You are responsible for 
others in the operating range of the equipment. 
Local safety requirements are fully applicable. Safety instructions in this 
document are complementary to the rules in force and do not supersede the 
latter. 

 

1.10  Equipment for 

Personal Protection 

When operating the device always wear: 

 

safety shoes (with steel top), 

 

tough gloves. 

 

1.11  Behaviour in 

Emergencies 

An emergency situation exists when 

 

power suddenly fails (device switches off), a horn signal sounds. 

 

the vacuum pressure drops below -0.125 bar to the red section on the scale 

of the pressure gauge, a horn signal sounds. 

Put the load down immediately if possible. If this is not possible, immediately 
leave the dangerous area near the load. It will fall off! 

 

Summary of Contents for VacuMaster Multi 400-1

Page 1: ...A 30 30 01 00221 00 J Schmalz GmbH Aacher Stra e 29 D 72293 Glatten Tel 49 7443 2403 0 Fax 49 7443 2403 259 http www schmalz de e mail schmalz schmalz de Status 03 2013 Page 1 18 Please keep this manu...

Page 2: ...evices 2 Technical Data 3 Description 3 1 Components of the Lifting Device 3 2 Blower with Reversing Device 3 3 Swivelling Unit only MULTI 90 3 4 Controls 3 5 Suction boxes pads 4 Installation 4 1 Gen...

Page 3: ...Operating Manual Blower Gebl K10 DG 14 Spare Part List Blower Gebl K10 DG 14 Electrical Connection Diagram EU Conformity Declaration Special features The unit is equipped with the following special f...

Page 4: ...he operating instructions and especially the chapter Safety therein Your company must ensure by internal measures that the operators of the lifting device are properly trained that they have read and...

Page 5: ...f possible If this is not possible immediately leave the dangerous area near the load Danger The device generates a very strong suction which can draw in hair and clothing Do not look into the suction...

Page 6: ...Check all suction hoses and clamps for proper mounting if necessary retighten the clamps Checking the warning signal Switch on the lifting device Place it on a board suck the board Danger Attention O...

Page 7: ...Blower 50 Hz 3 230 400 V 0 95 kW optional 60 Hz 3 255 440 V 1 6 kW Electric swivelling motor 50 Hz 3 230 400 V 0 25 kW 60 Hz 3 250 440 V 0 25 kW Weight ca 75 kg ca 105 kg ca 105 kg ca 130 kg ca 135 k...

Page 8: ...2013 Page 8 18 3 Description 3 1 Components of the Lifting Device The parts with safety function appear in bold type Pos Description Pos Description 1 Blower 8 Switch box 2 Reversing Device 9 Clampin...

Page 9: ...00221 00 Status 03 2013 Page 9 18 The parts with safety function appear in bold type Pos Description Pos Description 1 Blower 9 Clamping lever 2 Reversing Device 10 Star grip 3 Swivelling Unit 11 Ball...

Page 10: ...A springloaded brake stops the swivelling In the beginning a thin grease residue may show on the drive shaft and air relief valve This is normal and no reason to worry 3 4 Controls The controls are mo...

Page 11: ...the supply cable with plug from the control box Connect the cable to the power supply of the crane or hoist according to local regulations This job must be done by a qualified electrician Be sure that...

Page 12: ...oads when the vacuum is below 0 125 bar When the pointer of the pressure gauge moves into the red danger zone below 0 125 bar put the load down immediately When the horn blows put the load down immedi...

Page 13: ...n activating a Release button Crushing hazard Hold both Release buttons 3 and raise the lifting device 5 5 Switch on off the back suction pad row To remove boards from racks the back suction pad row c...

Page 14: ...does not suck wrong rotation direction Check and correct connection reversing unit do not work Check control reverse jammed clean it filter get choked Replace clean filter Blower dropped out power on...

Page 15: ...n swivelling devices gearwheel cover securely fitted X X Inspect and maintain the blower and reversing unit as described in the operating instructions See operating instructions for blower and reversi...

Page 16: ...wivel Unit only MULTI 90 The oil in the gearbox of the swivel head must be changed after 10 000 operating hours or after three years whichever occurs sooner Oil capacity 0 2 litres To change the oil f...

Page 17: ...e for leaks once per month Place the suction pads on an airtight smooth surface such as a sheet of metal Switch on the vacuum blower and suck on the workpiece A vacuum of at least 0 15 bar has to be r...

Page 18: ...x load must not be exceeded 9 Guarantee spare and consumable parts This equipment is guaranteed in accordance with our General Conditions of Business This also applies to spare parts where these are o...