7.8 Leak Test
Check the device for leaks once per month.
Place the suction pads on an airtight, smooth surface such as a sheet of
metal.
Switch on the vacuum blower and suck on the workpiece.
A vacuum of at least
–0.15 bar has to be reached.
If you don´t reach this vacuum, check:
the suction pads, seals, hoses, connections for damage or leaks,
if so, clean or replace it.
7.9 Inspection by a
Qualified Person
Accident prevention rules require a yearly inspection of lifting device and crane by
a qualified person.