background image

Operating Manual 

V

ACU

M

ASTER

 Multi-Serie 

Chapter 6 

Trouble Shooting

 

J. Schmalz GmbH 
Aacher Straße  29 
D  - 72293 Glatten 
Tel  +49 +7443 / 2403 - 0 
Fax +49 +7443 / 2403 - 259 
http://www.schmalz.de 
e-mail: [email protected] 

 

 

BA 30.30.01.00221-00 

Status 03.2013 

Page 14/18 

Troubleshooting 

The device must be installed and maintained by qualified personnel, 
mechanics and electricians. Any work on the electrical equipment may be 
carried out only by a qualified electrician. 

After each repair or maintenance job check the guards as described in the 
Operating Manual “Safety”. 

 

 

Error 

Cause 

Remedy 

Blower does not run 

wrongly connected 

check and correct connection 

motor overload switch tripped 

check, motor for defect, thermal overload? 
(let it cool down), clean dust filter  

power on two phases only 

check connection and fuse 

current consumption too high 

Check motor for defect, thermal overload? 
(let it cool down), clean dust filter 

power supply failure 

Check supply line 

Blower runs, but does 
not suck 

wrong rotation direction 

Check and correct connection 

reversing unit do not work 

Check control reverse jammed, clean it. 

filter get choked 

Replace / clean filter 

Blower dropped out 

power on two phases only 

Check connection and fuses 
Check current consumption 

supply power failure 

Check supply line 

current consumption too high 

Check motor for defect, thermal overload? 
(let it cool down), clean dust filter 

Gear motor does not 
run 

supply power failure 

Check supply line 

gear motor defective 

Repair / replace gear motor 

Vacuum pressure does 
not reach -0.125 bar 

D

ANGER

!

 

Do not lift the item. It will 
fall off! 

workpiece has cracks, openings or is 
porous 

- - - 

seal damaged 

Glue it, replace seal 

pressure gauge defective 

replace pressure gauge 

Horn blows without a 
recognizable reason 

Workpiece has cracks or openings 
or is porous 

Such workpieces cannot be handled with 
this lifting device 

Sealing lip / suction pad is damaged  Replace the sealing lip / suction pad 
hose defective / connectors not tight  replace components 
Vacuum switch defective or set 
wrongly 

Call customer service 

Limit switch to inquiry work pieces 
defective 

Check connection, readjust / replace 

 

Summary of Contents for VacuMaster Multi 400-1

Page 1: ...A 30 30 01 00221 00 J Schmalz GmbH Aacher Stra e 29 D 72293 Glatten Tel 49 7443 2403 0 Fax 49 7443 2403 259 http www schmalz de e mail schmalz schmalz de Status 03 2013 Page 1 18 Please keep this manu...

Page 2: ...evices 2 Technical Data 3 Description 3 1 Components of the Lifting Device 3 2 Blower with Reversing Device 3 3 Swivelling Unit only MULTI 90 3 4 Controls 3 5 Suction boxes pads 4 Installation 4 1 Gen...

Page 3: ...Operating Manual Blower Gebl K10 DG 14 Spare Part List Blower Gebl K10 DG 14 Electrical Connection Diagram EU Conformity Declaration Special features The unit is equipped with the following special f...

Page 4: ...he operating instructions and especially the chapter Safety therein Your company must ensure by internal measures that the operators of the lifting device are properly trained that they have read and...

Page 5: ...f possible If this is not possible immediately leave the dangerous area near the load Danger The device generates a very strong suction which can draw in hair and clothing Do not look into the suction...

Page 6: ...Check all suction hoses and clamps for proper mounting if necessary retighten the clamps Checking the warning signal Switch on the lifting device Place it on a board suck the board Danger Attention O...

Page 7: ...Blower 50 Hz 3 230 400 V 0 95 kW optional 60 Hz 3 255 440 V 1 6 kW Electric swivelling motor 50 Hz 3 230 400 V 0 25 kW 60 Hz 3 250 440 V 0 25 kW Weight ca 75 kg ca 105 kg ca 105 kg ca 130 kg ca 135 k...

Page 8: ...2013 Page 8 18 3 Description 3 1 Components of the Lifting Device The parts with safety function appear in bold type Pos Description Pos Description 1 Blower 8 Switch box 2 Reversing Device 9 Clampin...

Page 9: ...00221 00 Status 03 2013 Page 9 18 The parts with safety function appear in bold type Pos Description Pos Description 1 Blower 9 Clamping lever 2 Reversing Device 10 Star grip 3 Swivelling Unit 11 Ball...

Page 10: ...A springloaded brake stops the swivelling In the beginning a thin grease residue may show on the drive shaft and air relief valve This is normal and no reason to worry 3 4 Controls The controls are mo...

Page 11: ...the supply cable with plug from the control box Connect the cable to the power supply of the crane or hoist according to local regulations This job must be done by a qualified electrician Be sure that...

Page 12: ...oads when the vacuum is below 0 125 bar When the pointer of the pressure gauge moves into the red danger zone below 0 125 bar put the load down immediately When the horn blows put the load down immedi...

Page 13: ...n activating a Release button Crushing hazard Hold both Release buttons 3 and raise the lifting device 5 5 Switch on off the back suction pad row To remove boards from racks the back suction pad row c...

Page 14: ...does not suck wrong rotation direction Check and correct connection reversing unit do not work Check control reverse jammed clean it filter get choked Replace clean filter Blower dropped out power on...

Page 15: ...n swivelling devices gearwheel cover securely fitted X X Inspect and maintain the blower and reversing unit as described in the operating instructions See operating instructions for blower and reversi...

Page 16: ...wivel Unit only MULTI 90 The oil in the gearbox of the swivel head must be changed after 10 000 operating hours or after three years whichever occurs sooner Oil capacity 0 2 litres To change the oil f...

Page 17: ...e for leaks once per month Place the suction pads on an airtight smooth surface such as a sheet of metal Switch on the vacuum blower and suck on the workpiece A vacuum of at least 0 15 bar has to be r...

Page 18: ...x load must not be exceeded 9 Guarantee spare and consumable parts This equipment is guaranteed in accordance with our General Conditions of Business This also applies to spare parts where these are o...

Reviews: