6
Troubleshooting
The device must be installed and maintained by qualified personnel,
mechanics and electricians. Any work on the electrical equipment may be
carried out only by a qualified electrician.
After each repair or maintenance job check the guards as described in the
Operating Manual “Safety”.
Error
Cause
Remedy
Blower does not run
wrongly connected
check and correct connection
motor overload switch tripped
check, motor for defect, thermal overload?
(let it cool down), clean dust filter
power on two phases only
check connection and fuse
current consumption too high
Check motor for defect, thermal overload?
(let it cool down), clean dust filter
power supply failure
Check supply line
Blower runs, but does
not suck
wrong rotation direction
Check and correct connection
reversing unit do not work
Check control reverse jammed, clean it.
filter get choked
Replace / clean filter
Blower dropped out
power on two phases only
Check connection and fuses
Check current consumption
supply power failure
Check supply line
current consumption too high
Check motor for defect, thermal overload?
(let it cool down), clean dust filter
Gear motor does not
run
supply power failure
Check supply line
gear motor defective
Repair / replace gear motor
Vacuum pressure does
not reach -0.125 bar
D
ANGER
!
Do not lift the item. It will
fall off!
workpiece has cracks, openings or is
porous
- - -
seal damaged
Glue it, replace seal
pressure gauge defective
replace pressure gauge
Horn blows without a
recognizable reason
Workpiece has cracks or openings
or is porous
Such workpieces cannot be handled with
this lifting device
Sealing lip / suction pad is damaged Replace the sealing lip / suction pad
hose defective / connectors not tight replace components
Vacuum switch defective or set
wrongly
Call customer service
Limit switch to inquiry work pieces
defective
Check connection, readjust / replace