Interfaces
EN-US · 30.30.01.01598 · 02 · 01/18
43 / 74
Bit 6 = Supply pressure too low (<1.9 bar) or too high (>6.3 bar)
Bit 7 = Error in one or more ejectors
Default value
0
Unit
-
EEPROM
no
Extended Device Status Event Category
Parameter
138 (0x008A)
Description
Extended device status – event category
Index
1: Event category of current device status
Data type
uint16
Length
1 bytes
Access
Read only
Value range
0x10: Device is operating properly
0x21: Warning, low
0x22: Warning, high
0x41: Critical condition, low
0x42: Critical condition, high
0x81: Defect/fault, low
0x82: Defect/fault, high
Default value
-
Unit
-
EEPROM
no
Extended Device Status – Event code
Parameter
138 (0x008A)
Descrip-
tion
Extended Device Status – Event code
Index
2: Event category of current device status
Data type
uint16
Length
1 bytes
Access
Read only
Value
range
Event Code
0x5100
0x5110
0x5112
0x1812
0x1802
0x1811
0x1000
0x8C01
0x180C
0x180D
0x180E
0x8C20 to 8C2F
Event Name
Primary supply voltage (US) too low
Primary supply voltage (US) too high
Secondary supply voltage (UA) too low
Secondary supply voltage (UA) too high
Input pressure too high (>6.3 bar) or too low
(<1.9 bar)
Internal error, user data corrupted
Internal error, bus fault
Manual mode is active in at least one ejector
Condition monitoring: primary supply voltage
US outside of operating range
Condition monitoring: secondary supply volt-
age outside of operating range
Condition Monitoring: supply pressure outside
of operating range (3.5 to 5 bar)
Calibration fail, ejectors #1 to #16
Status Category
Critical condition, high
Critical condition, high
Critical condition, high
Critical condition, high
Critical condition, high
Defect/fault, high
Defect/fault, high
Warning, low
Warning, high
Warning, high
Warning, high
Defect/fault, low