Interfaces
44 / 74
EN-US · 30.30.01.01598 · 02 · 01/18
0x8D00 to
8D0F
0x8D10 to
8D1F
0x8D20 to
8D2F
0x8D30 to
8D3F
0x8D40 to
8D4F
0x8D50 to
8D5F
Measurement range overrun, ejectors #1 to
#16
Valve protection active, ejectors #1 to #16
Evacuation time t1 is greater than limit, ejec-
tors #1 to #16
Leakage rate is greater than limit, ejectors #1
to #16
H1 was not reached, ejector #1 to #16
Free-flow vacuum level too high, ejector #1 to
#16
Defect/fault, low
Warning, high
Warning, low
Warning, low
Warning, high
Warning, low
Default
value
-
Unit
-
EEPROM
no
NFC status
Parameter
139 (0x008B)
Description
NFC status
Index
-
Data type
uint8
Length
1 bytes
Access
Read only
Value range
0x00: data valid, write finished successfully
0x23: write failed: write access locked
0x30: write failed: parameter(s) out of range
0x41: write failed: parameter set inconsistent
0xA1: write failed: invalid authorization
0xA2: NFC not available
0xA3: write failed: invalid data structure
0xA5: write pending
0xA6: NFC internal error
Default value
-
Unit
-
EEPROM
no
Total Suction Cycles Counter for the Ejectors
Parameter
140 (0x008C)
Description
Vacuum-on counter for ejector
Index
Index 0 to 15 corresponds to ejector #1 to #16
Data type
uint32
Length
64 bytes
Access
Read only
Value range
0 to 999,999,999