background image

GS1100 Series     

 

 

 

 

 

 

 

GuardScan Guard Tour Terminal 

 

Manual  Part  Number  :  TM951199  REV  :  02                                                Dev  2009     

GIGA-TMS 

REGISTERED TO ISO 9001:2000 

 

8F, No.31, Lane 169, Kang-Ning St., Hsi-Chih Taipei Hsien, 221 Taiwan 

Phone: (886) 2-2695-4214   

FAX: (886) 2-2695-4213   

www.gigatms.com.tw   

Summary of Contents for GuardScan Guard Tour GS1100 Series

Page 1: ...Guard Tour Terminal Manual Part Number TM951199 REV 02 Dev 2009 GIGA TMS REGISTERED TO ISO 9001 2000 8F No 31 Lane 169 Kang Ning St Hsi Chih Taipei Hsien 221 Taiwan Phone 886 2 2695 4214 FAX 886 2 2695 4213 www gigatms com tw ...

Page 2: ...out notice No part of this document may be reproduced or transmitted in any form or by any means electronic or mechanical for any purpose without the express written permission of GIGA TMS Inc REVISIONS Rev Number Date Note 01 Oct 2007 Initial Release 02 Dev 2009 Update GuardScan Monitor ...

Page 3: ... scan button of the terminal to read several RFID tags 3 Connect the terminal to your PC with the communication cable The green LED will keep blinking that indicates the terminal is under communication mode 4 Launch GuardScan Monitor program On General Commands tab select the connected COM port Click Download Data to download all data from the terminal to your PC The screen shot will appear as bel...

Page 4: ...esign of vibration feedback keeps your reading work to be more focus and completed The situation of lack of battery power will not happen to you any more because of the vibration design feedback which will not work when battery power is low Use our application software Patrol Manager optional you may set up a remarkable Patrol Management System Table Contents 1 Overview on GS1100 Handset 5 2 Overv...

Page 5: ...to start the data reading 2 Status indicating LED served as the GS1100 handset status indication 3 Sensing field the effective working area of RFID Tag scanning 4 Communication port to complete the work of data uploading and downloading via the communication cable to a PC 5 Battery Lid the position of changing battery ...

Page 6: ...ps B L LED 1 blink SCAN LED 2 blinks every 2 seconds X X RTC Abnormal Press and hold the SCAN button for 10 seconds SCAN LED 1 blink 3 short beeps B L LED 1 blink SCAN LED 3 blinks every 2 seconds X X Battery Low Press and hold the SCAN button for 20 seconds SCAN LED lights for 10 seconds B L LED 1 blink every 2 seconds O X EEPROM Fail Press and hold the SCAN button for 10 seconds SCAN LED 1 blink...

Page 7: ...7 Overview on GS1100 Accessories USB Cable RS232 Cable CABLE P N WAS XXXX REV X Software and User Manual Battery Cover ...

Page 8: ... head at the RFID tag and press the Scan button till the GREEN SCAN LED turns ON to read the RFID tag Meanwhile you will hear one beep which means a successful reading is achieved then the GREEN SCAN LED will turns off and GS1100 body shakes Note The GREEN SCAN LED will go off in 10 seconds if the scanning RFID tag failed illustration 2 RFID Tag ...

Page 9: ...ou have completed the work of Data Uploading to the PC The handset will switch off automatically after 3 minutes once it is not communicating with the PC illustration 3 Personal Computer U S B P O R T or RS232 PORT Indication of Battery Low Shown as illustration 4 when you press the Power Scanning button on the GS1100 for 10 seconds the RED B L LED will start to flash once at every 2 seconds then ...

Page 10: ...s three beep beep beep then the GREEN SCAN LED blinks two times at every 2 seconds and stops 10 seconds later The GS1100 is not able to read any RFID Tags This indicates that the Memory inside the GS1100 is full and the data in the Memory should be downloaded Changing Battery Please follow the illustration 5 for battery replacement illustration 5 ...

Page 11: ...lly for the program installation Launch Program 1 From Start Programs GIGA TMS click GuardScan Monitor 2 A Password Required window will pop up enter correct password default is 0000 and then go to GuardScan Monitor program main window Hardware Connection 1 Connect the terminal to COM port or USB port of your PC with the communication cable The green LED will keep blinking that indicates the termi...

Page 12: ...date time d Get Time Get GS1100 s time value and show in the Message box e Get Mach Get GS1100 s machine number and show in the Message box f Get Version Get GS1100 s firmware version and show in the Message box g Power Down Turn off the GS1100 h Record Count Get the total number of scanned tag s and show the number in the Message box i Download Data Transfer the scanned tag s data from GS1100 to ...

Page 13: ...iguration Miscellaneous tab a Clearing the data of terminal If this item is selected GS1100 s data will be erased after the data is downloaded successfully b Updating the time of terminal If this item is selected GS1100 s date time will be synchronized to PC s date time after the data is downloaded successfully c Turning off the power of terminal If this item is selected GS1100 s power will be tur...

Page 14: ...f GuardScan Monitor cannot work properly with GS1100 please check it up according to following procedures Check if GS1100 is equipped with the battery Check if GS1100 is connected with the communication cable correctly and the cable is connected to the COM port of PC correctly Check if the Green SCAN LED of GS1100 keeps blinking Check if the Comm Port selection in GuardScan Monitor is correct Afte...

Page 15: ...end of data exchange ENQ 05H E Marks the beginning of command packet ACK 06H F Acknowledges reception of data NAK 15H U Requests data retransmission ETB 17H W Signals that command or data was not accepted There are two different packet types command packets and data packets Command packets start with ENQ character and contain a machine number of the GS1100 addressed and command code COMMAND FORMAT...

Page 16: ...byte and control characters In many cases reception of data must be acknowledged by the receiving side This is done by sending the ACK character In case the receiving side does not accept the data for whatever reason the NAK character may be sent to request retransmission Summarized below are all supported commands COMMAND INDEX TABLE Command ASCII Description S 53H Set date time T 54H Get date ti...

Page 17: ...ple even with the month set to 13 Use new T command to verify if new date and time were actually set Get date time T 54H PC to GS1100 ENQ M T GS1100 to PC STX date time field ETX BCC PC to GS1100 ACK NAK GS1100 to PC EOT Date time field has the following format YYYYMMDDhhmmss where YYYY year MM month DD date hh hour mm minutes ss seconds Download database data I 49H PC to GS1100 ENQ M I GS1100 to ...

Page 18: ...cover database data M 4DH PC to GS1100 ENQ M M GS1100 to PC ACK PC to GS1100 EOT This command alters log database in such a way that it appears to be 100 full Subsequent I command will download the contents of entire log database memory This command therefore can be used for data recovery purposes Get total number of records in the database A 41H PC to GS1100 ENQ M A GS1100 to PC STX number of rec...

Page 19: ...ny kind of ASCII data in it we commit to the following format Vx xx pp p nn n where Vx xx version number i e V1 25 pp p product model number i e GS1100 nn n note i e rev 01 01 2000 Version number product model number and note fields are separated by space characters Version number and product model number are guaranteed to contain no space characters Note field can contain any characters including...

Page 20: ...Mode F 46H PC to GS1100 ENQ M F GS1100 to PC ACK It is used to reset initial value of GS1100 for the manufacture Not Recommended for user s software Go to ISP Mode X 58H PC to GS1100 ENQ M X GS1100 to PC ACK This command puts the GS1100 into the Firmware Management Mode FMM FMM allows you to quickly upgrade your GS1100 s internal firmware and also check validity of currently loaded firmware Contac...

Page 21: ...h your local distributor for the latest version ROM T0836 Connect GS1100 to PC comm Port Press the Power Scanning button for 1 second to make GS1100 enter into communication mode 2 Being using your Rom Manager software by selecting GS1100 connection to PC communication port 3 Click Update button and select the path ROM T0836 and press Yes to access the updating ...

Page 22: ... able to follow above procedure to complete the firmware updating By avoiding this you may connect USB cable into PC comm port or USB port connect communication cable into GS1100 communication port and press the Scan button till the RED B L LED lights up Now GS1100 is in the mode of ISP you may follow the procedure from 3 to 4 to continue the updating ...

Page 23: ...ion two beeps will sound and the RED B L LED will light up GS1100 Handset with RFID tags reading test Then we go for the 2nd step At this point you will see the GREEN SCAN LED and RED B L LED are in cross flashing when you hold up the GS1100 handset Following you need to scan the RFID tags for data reading with 5 times to make sure the hardware is functional Every record of data reading a beep sou...

Page 24: ... specification DC 1 5 volt No 3 battery brand new Duracell MN1500 LR6 DC1 5V battery Communication interface RS232 GS1100 USB GS1100U Protocol 19200bps 8 N 1 Physical dimension L 165 mm W 48mm H 34 mm Weight 120 grams without battery Certificate CE FCC EN 55022 Class A EN 61000 3 2 Class A EN 61000 3 3 Class A EN 55024 Class A EN61000 4 2 Class A EN61000 4 3 Class A EN61000 4 4 Class A EN61000 4 5...

Reviews: