background image

DRAFT 3

TD9300 Data Terminal

Installation Manual

MNE-00003-01 · Issue 1 · March 2015

Summary of Contents for TD9300

Page 1: ...DRAFT 3 TD9300 Data Terminal Installation Manual MNE 00003 01 Issue 1 March 2015 ...

Page 2: ...888 NZ600346 NZ607046 NZ610426 NZ610563 NZ615954 NZ625717 NZ628342 NZ629167 NZ630718 NZ700387 NZ700908 NZ70177 AU2004216984 AU321864 AU321868 AU339127 AU339391 CN1031871 CN1070368 CN200930004199 5 CN200930004200 4 CN200930009301 0 EU000915475 0001 EU000915475 0002 GB2413445 US 8301682 US13 542147 US13 896969 US14 032876 US14 495334 US29 401234 US29 401235 US5745840 US640974 US640977 US7411461 US77...

Page 3: ...1 2 3 Anti tampering Devices 9 1 2 4 ESD Precautions 10 1 3 Environmental Conditions 11 1 3 1 Operating Temperature Range 11 1 3 2 Humidity 11 1 3 3 Dust and Dirt 11 1 3 4 Grounding and Lightning Protection 11 1 3 5 Equipment Ventilation 11 1 4 Regulatory Information 12 1 4 1 Distress Frequencies 12 1 4 2 Compliance Standards 12 1 4 3 Radio Frequency Emissions Limits in the USA 12 1 4 4 Radio Freq...

Page 4: ...ual Tait Limited March 2015 5 Getting Started 25 5 1 Confirming Operation 25 6 Specifications 27 General 28 Serial Ports 28 Ethernet Interface 28 Digital Inputs and Outputs 29 Compliance Standards 29 Tait Software License Agreement 31 ...

Page 5: ...u tree to display its page Within this manual four types of alerts may be given to the reader The following paragraphs illustrate each type of alert and its associated symbol Warning This alert is used when there is a hazardous situation which if not avoided could result in death or serious injury Caution This alert is used when there is a hazardous situation which if not avoided could result in m...

Page 6: ...ons for Tait products to provide technical details not included in manuals and to offer solutions for any problems that arise Look for new or updated technical notes on the Tait Technical Resources website All available product documentation is provided on the Product CDs supplied with individual items of equipment Updates may also be published on the Tait Technical Resources website Printed copie...

Page 7: ... at multi transmitter sites must be installed so that they comply with the relevant RF exposure standards a Reference Standards Health Canada s Safety Code 6 Limits of Human Exposure to Radiofrequency Electromagnetic Energy in the Frequency Range from 3kHz to 300GHz USA Federal Communications Commission OET bulletin 65 47CFR 1 1310 IEEE C95 1 2005 Standard for Safety Levels with Respect to Human E...

Page 8: ...ité 6 de Santé Canada Limites d exposition humaine à l énergie électromagnétique radioélectrique dans la gamme de fréquences de 3kHz à 300GHz Commission fédérale des communications FCC des Etats Unis d Amérique bulletin OET numéro 65 47CFR 1 1310 IEEE C95 1 2005 Norme pour les niveaux de sécurité compatibles avec l exposition des personnes aux champs électromagnétiques de radiofréquence 3kHz à 300...

Page 9: ...f locked cabinets and the use of seals on connectors All network and audio connectors should be sealed with the stick on type of seal The purpose of the seals is to detect unauthorized tampering The seal should reveal if any of the connectors have been unplugged or if any unauthorized equipment has been plugged in The seals must be difficult to remove without breaking and must bridge between the c...

Page 10: ...s We recommend you purchase an antistatic bench kit from a reputable manufacturer and install and test it according to the manufacturer s instructions Figure 1 1 shows a typical antistatic bench set up You can obtain further information on antistatic precautions and the dangers of electrostatic discharge ESD from standards such as ANSI ESD S20 20 1999 or BS EN 100015 4 1994 Figure 1 1 Typical anti...

Page 11: ...nt panel connectors facing down 1 3 4 Grounding and Lightning Protection Electrical Ground A threaded grounding connector is provided on the front panel for connection to the site ground point refer to Overview of Inputs and Outputs on page 20 for more details Lightning Ground It is extremely important for the security of the site and its equipment that you take adequate precautions against lightn...

Page 12: ... 15 19 a 3 All Others This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 1 4 4 Radio Frequency Emissions Limits in Canada This device complies with Industry Canada licence exempt RSS s...

Page 13: ...twork to exchange DMR control channel and packet data messages with the Tait SCADA Gateway The TD9300 transfers industry standard SCADA protocols over its RS 232 RS 485 and Ethernet interfaces to allow interconnection to industrial control equipment such as RTUs and IEDs The TD9300 can be installed in pole mounted or other box enclosures refer to Installation on page 15 The operating temperature r...

Page 14: ...DRAFT 3 14 Introduction TD9300 Installation Manual Tait Limited March 2015 ...

Page 15: ...surements for these mounting holes are provided in Figure 3 3 on page 18 The TD9300 has an IP40 rating when mounted in any orientation It also has an IP51 rating dust category 2 when mounted with the front panel connectors facing down If access to the rear of the TD9300 is restricted when it is installed it may be difficult to release the latch to remove the unit at a later date Before mounting th...

Page 16: ...16 Installation TD9300 Installation Manual Tait Limited March 2015 Figure 3 1 DIN rail mounting 35mm DIN rail b c Mounting Removal d e f Recommended mounting method M3 Taptite screw x4 torque to 15lbf in 1 7N m ...

Page 17: ...DRAFT 3 TD9300 Installation Manual Installation 17 Tait Limited March 2015 Figure 3 2 Flat mounting M4 Taptite screw x4 torque to 22lbf in 2 5 N m ...

Page 18: ... Installation Manual Tait Limited March 2015 Figure 3 3 Location of mounting holes in the chassis 2 38 in 60 5 mm 6 5 in 165 mm 2 38 in 60 5 mm M3 Taptite x10 M4 Taptite x4 1 42 in 36 mm 1 42 in 36 mm 3 94 in 100 mm 3 45 in 87 5 mm ...

Page 19: ...DRAFT 3 TD9300 Installation Manual Connection 19 Tait Limited March 2015 4 Connection This chapter provides detailed information on connecting the various inputs and outputs on the front panel ...

Page 20: ...lso used to configure the TD9300 via a web browser It is a 10BASE T or 100BASE T connection The green link speed LED indicates the negotiated link speed The LED is lit when the link speed is 100BASE T The amber link status and activity LED is lit when the link is active and flashes when activity is present d Serial RS 232 RS 485 Serial RS 232 RS 485 connection 1 is used to connect to an RTU IED e ...

Page 21: ...reen DMR LED is lit when the TD9300 is registered on the DMR network j 1 LED Reserved for future use 1 2 LED Reserved for future use 1 DC input Connect a 9 36VDC power supply to this input using the supplied connector The maximum current drawn by the TD9300 is 4 5A at 24VDC when transmitting at 25W Refer to Connecting DC Power on page 23 for more information 1 Ground M4 chassis ground connector An...

Page 22: ...mit data 3 receive data 4 not connected 5 not connected 6 receive data 7 not connected 8 not connected 1 2 3 4 5 6 7 8 external view Pin Description 1 not connected 2 not connected 3 not connected 4 ground 5 receive data output 6 transmit data input 7 clear to send output 8 request to send input 1 2 3 4 5 6 7 8 external view serial 1 shown Pin Description 1 input 1 A 2 input 1 B 3 input 2 A 4 inpu...

Page 23: ...ept an input of 9 36VDC 12 or 24VDC nominal with negative ground The TD9300 is powered down by disconnecting the front panel DC connector The pin allocations for the DC input on the TD9300 are given in the following table Pin Description 1 V input 2 V input What about a shutdown process for the Linux console 1 2 external view ...

Page 24: ...DRAFT 3 24 Connection TD9300 Installation Manual Tait Limited March 2015 4 4 System Connections Example connection diagram to be supplied later ...

Page 25: ...go in this chapter LED Color State Power green off steady power is not connected to the TD9300 power is connected to the TD9300 RTU status green off steady the RTU is not linked to the TD9300 the RTU is linked to the TD9300 DMR green off steady the TD9300 is not registered on the DMR network the TD9300 is registered on the DMR network 1 reserved for future use 2 reserved for future use Ethernet li...

Page 26: ...DRAFT 3 26 Getting Started TD9300 Installation Manual Tait Limited March 2015 ...

Page 27: ...wise indicated e g typical for equipment operating at standard room temperature 71 6 F to 82 4 F 22 C to 28 C and standard test voltage 24VDC Where applicable the test methods used to obtain these figures are those described in the ETSI EN specifications You can obtain further details of test methods and the conditions which apply for compliance testing in all countries from Tait ...

Page 28: ...urrent at 24VDC 4 5A at 25W output power Operating Temperature Range 22 F to 140 F 30 C to 60 C ambient temperature Dimensions Height Width Length 2 4in 61mm 7 1in 180mm 6 1in 156mm Weight 4 2lb 1 9kg Serial Ports Port Type DCE Tx Rx CTS RTS Signal Levels RS 232 and RS 485 compatible Format 8 bit ASCII 1 stop bit no parity Baud Rate 1200 to 115 200 bps Ethernet Interface Transceiver 10 100Base T I...

Page 29: ...0mA NO NC VOL 0 6V IOL 250mA VOH 3 5V TTL and 5V CMOS compatible IOH 100µA 0 3V VOH 30V transients outside this range may be clamped IOH 6mA VOH 30V pulled up through an external load Compliance Standards Where applicable this equipment has been tested and approved to the following standards EMC EN 301 489 1 EN 301 489 5 EN 300 113 CFR Title 47 Part 15 RSS 119 ICES 003 AS NZS 4768 Safety EN 60950 ...

Page 30: ...DRAFT 3 30 Specifications TD9300 Installation Manual Tait Limited March 2015 ...

Page 31: ...ions de compilations disas semblies emulations enhancements fixes mod ifications translations and updates to or deriva tive works from the Software or Documentation whether made by Tait or another party or any improvements that result from Tait processes or provision of information services Licensee means any individual or entity that has accepted the terms of this License Open Source Software mea...

Page 32: ...se of the Software 4 3 Unless otherwise authorized by Tait in writ ing Licensee will not and will not enable or allow any third party to i install a copy of the Software on more than one unit of a Designated Product or ii copy or transfer Software installed on one unit of a Designated Product to any other device Licensee may temporarily transfer Software installed on a Designated Prod uct to anoth...

Page 33: ...ubcontractor integrator is purchasing Tait Designated Prod ucts and licensing Software not for its own inter nal use but for end use only by a Customer the Licensee may transfer such Software but only if a Licensee transfers all copies of such Software and the related Documentation to the transferee and b Licensee has first obtained from its Cus tomer and if Licensee is acting as a subcontrac tor ...

Page 34: ...L Sections 4 5 6 3 7 8 9 10 and 11 survive the termination of this Agree ment 11 7 ORDER OF PRECEDENCE In the event of inconsistencies between this Agreement and any other Agreement between the parties the parties agree that with respect to the specific subject matter of this Agreement this Agreement prevails 11 8 SECURITY Tait uses reasonable means in the design and writing of its own Software an...