MEASURES FOR ENSURING SAFE OPERATING PERIODS
30.30.01.01117/06
www.schmalz.com
EN | 43
8.2 General Overhaul
A general overhaul must be performed once the theoretical usage period is reached (or at the latest
after 10 years if not using a plant data collection device). This is to ensure that the device is in
sufficient condition to allow safe operation for a further usage period. The components must be
checked and replaced in accordance with Table 11. The inspection and approval for continued use
must be performed by a specialist company authorized by the manufacturer or by the manufacturer
themselves.
The inspector determines:
What new theoretical usage period is possible
The maximum period of time until the next general overhaul
This information must be recorded in the inspection book.
Table 11: General overhaul
Components for all types
of SCH models
Check for wear *
Replace
Brake
X
Motor shaft
X
Gear teeth
X
Bearings
X
Gaskets
X
Chain
X
Chain wheel, chain guide
X
Guide wheels
X
Hanger
X
Load hook
X
Trolley, impellers
X
Guards, limit switch
X
*)