TECHNICAL DATA
30.30.01.01117/06
www.schmalz.com
EN | 15
3 Technical Data
3.1 Drive Group
Table 2: Limit values for the drive groups
Drive groups according to FEM 9.511
1Bm
1Am
2m
3m
4m
5m
Drive groups according to ISO 4301-1
M3
M4
M5
M6
M7
M7
Speed changes (S) per hour
150 S/h
180 S/h
240 S/h
300 S/h
360 S/h
360 S/h
Duty cycle
< 25%
< 30%
< 40%
< 50%
< 60%
< 60%
Maximum permitted lift capacity in the drive groups according to FEM 9.511 / ISO 4301-1
Table 3: Drive group
Type
Chain
strands
Speed at 50 Hz
Speed at 60 Hz
1Bm / M3
1Am / M4
2m / M5
3m / M6
4m / M7
SCH-S
1
8/2 m/min
9.6/2.4 m/min
-
350 kg
250 kg
200 kg
160 kg*
SCH-M
1
8/2 m/min
9.6/2.4 m/min
800 kg
650 kg
500 kg
400 kg
350 kg**
SCH-M
2
4/1 m/min
4.8/1.2 m/min
-
1,250 kg
1,000 kg
800 kg
650 kg**
SCH-M-FU
1
6.9
– 0.7 m/min
6.9
– 0.7 m/min
-
-
-
650 kg
500 kg**
SCH-M-FU
21
3.5
– 0.3 m/min
3.5
– 0.3 m/min
-
-
-
1,250 kg 1,000 kg**
SCH-L
1
8/2 m/min
9.6/2.4 m/min
1,600 kg
1,250 kg
1,000 kg
800 kg
650 kg
SCH-L
2
4/1 m/min
4.8/1.2 m/min
-
2,500 kg
2,000 kg
1,600 kg
1,250 kg
SCH-L-FU
1
6.9
– 1.2 m/min
6.9
– 1.2 m/min
-
-
-
1,250 kg
1,000 kg
SCH-L-FU
2
3.5
– 0.6 m/min
3.5
– 0.6 m/min
-
-
-
2,500 kg
2,000 kg
*
1 chain: min. 80 kg
**
1 chain: min. 100 kg / 2 chains: min. 200 kg
3.2 Voltage Versions
Voltage
Frequency
Power [kW]
Main fuse
208V-AC3
60 Hz
0.45
6 A (slow acting)
230V AC3
60 Hz
0.45
6 A (slow acting)
380V AC3
60 Hz
0.45
6 A (slow acting)
400V AC3
50 Hz
0.37
6 A (slow acting)
460V AC3
60 Hz
0.45
6 A (slow acting)
575V AC3
60 Hz
0.45
6 A (slow acting)
Weight
With 3 m chain, load hook and chain box
SCH-S
SCH-M
SCH-L
Single Chain
Dual Chain
Single Chain
Dual Chain
19 kg
28 kg
31 kg
66 kg
72 kg