8
K.
Actuator Marking (According to 2014/34/EU Directive)
Please refer to the following example of actuator marking:
II 2 G c Tx
Where:
=
symbol of conformity to the EU applicable directives
=
ATEX symbol
II
=
group II (surface)
2
=
apparatus of category 2
G
=
explosive atmosphere with presence of gas, vapours, fogs
c
=
type of protection
Tx
=
temperature class
Hazardous area
Installation category according to ATEX Directive No. 2014/34/EU
Gas, fog or vapours
Zone 1
2 G
Gas, fog or vapours
Zone 2
3 G
ε
X
ε
X