14. Appendix
82|108
Reference Manual |Edition 4.0 (10-2013) |EcoCut 3300
14.3
PRE-/POSTFEED INTERFACE (PPI, OPTION)
On the postfeed connector a
Schleuniger
CableCoiler or WireStacker or a customer specific device may be
hooked up, see chapter
"14.3.1.1 POSTFEED connector (Page 82)"
NOTICE
Caution, property damage!
Basically the interface is protected against overload, short circuit, electrostatic
discharge and electromagnetic interference. With inappropriate use, overload
situations may occur which are not covered by the internal protection circuitry.
This can lead to malfunction or even damage to the
EcoCut 3300
.
14.3.1
POSTFEED interface
POSTFEED connector
RENCA
D-Sub 25-pin (F)
RENCA
+24 V
RDETECT
RIN0
RIN1/WSCONVEYORREADY
RIN2/CCSTART/WSBATCHREADY
RIN3/CCREADY/WSEJECTREADY
+24 V
RENCB
ROUT2/CCBINDING/WSBATCH
Gnd
Gnd
ROUT0
ROUT1/CCSTOP/WSCONVEYOR
ROUT3/CCEJECT/WSEJECT
Gnd
RENCB
Shield
POSTFEED
WSEJECT passive
Fig. 10: Pin assignment „POSTFEED“
Pin
Description
Function
Signal type
1
+ 24 V
-
Supply
-
2
/WSEJECT passive
Output for the ejection control of passive Wire-
Stackers
Output
NPN
3
-
(not implemented)
-
-
4
RDETECT
Wire sensing
Input
NPN
5
RIN0
Multifunction input
Input
PNP
Summary of Contents for EcoCut 3300
Page 8: ...Table of contents 8 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 22: ...4 Product specifications 22 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 74: ...12 Spare parts exploded view drawings 74 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 76: ...13 Decommissioning disposal 76 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 102: ...14 Appendix 102 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 103: ...Personal notes Reference Manual Edition 4 0 10 2013 EcoCut 3300 103 108...
Page 104: ...Personal notes 104 108 Reference Manual Edition 4 0 10 2013 EcoCut 3300...
Page 107: ......
Page 108: ......