20
AFTER SALES SUPPORT
1300 130 570
MODEL: AERO
2
SPADE PRODUCT CODE: 59540 04/2018
VIII. Cleaning and maintenance
m
Attention!
Always disconnect the device from the air supply before starting any
cleaning work.
Cleaning
•
Keep the device free of dirt and dust as far as possible. Wipe the device with a clean
cloth or blow it with compressed air at low pressure.
•
We recommend that you clean the device immediately each time you have finished
using it.
•
Clean the device regularly with a moist cloth and some soft soap. Do not use clean-
ing agents or solvents; these could attack the plastic parts of the device. Ensure
that no water can seep into the device.
Maintenance
If the regular oil supply to the device is assured, the device is maintenance-free.
IX. Technical data
Overall length (without connected tool)
820 mm
Operating pressure
6.3 bar
Air consumption, min. approx.
220 l/min
Air consumption, max. (at 6.3 bar)
280 l/min
Stroke rate, approx.
1800 - 1900 bpm
Tool receiver
18 mm
Recommended hose internal diameter
9 mm
Sound and vibration
The noise and vibration values have been developed with a standardised measure-
ment process.
Sound pressure level L
pA
89.59 dB(A)
Uncertainty K
pA
3 dB
Guaranteed sound power level L
WA
105 dB(A)
measured sound power level L
WA
100.59 dB(A)
Uncertainty K
WA
3 dB
Vibration left handle a
hd
16.22 m/s
2
AUS
Cleaning and maintenance/Technical data
AERO
2
SPADE
1300 855 831