Tighten the lock nut.
Fill the siphon with 8 strokes.
CAUTION! Do not fill with more than 8 strokes. The excess
oil may flow in the suction tubes. Additionally the excess oil
can remove the required oil in the siphon by a physical
suction effect through the draining channel.
Figure 27:
Filling pump inserted and fixed in the siphon block
Remove the filling pump.
Close the threaded hole with the plug (a small amount oil coming out does
not impact the functionality.
Clean the siphon block.
Continue with the next block.
3.3
Filling of pipe siphons for VN115/87plus EX system with oil
Figure 28:
Pipe siphon
Remove flexible hose
Fill in 70ml lubrication oil
Fix flexible hose again
Fitting to
flexible hose
and oil input