Scan Combiflex 1000 – User Guide
Chapter 5
- 30 -
SCANMASKIN
SW
ED
EN
A
B
MACHINES-MINERALS-KNOW-HOW
5.6.2
Remote control related faults
Symptom
Cause
Correction
A
8
The radio remote control
does not work
The connection was lost
Reinitialise the connection
O
The battery is empty on the remote control
Replace the battery to a charged one
O
The emergency stop button is depressed
Release the emergency stop button
O
The antenna is damaged
Replace the antenna
S
Table 5-2
Common faults – remote control
5.6.3
Transportation related faults
Symptom
Cause
Correction
A
9
Transportation does not
work while offline.
The batteries are empty
Charge the batteries
O
The batteries are damaged
Replace the batteries
S
Transportation does not
work at all.
The drive motors are not connected properly
Connect the motors
Table 5-3
Common faults – transportation
8
See access table ”Table 5-5”
9
See access table ”Table 5-5”