33
Parameter Number
Set value
Details
H1-
**
0
Multi-speed Reference 1
H1-
**
1
Multi-speed Reference 2
H1-
**
2
Multi-speed Reference 3
Different speed reference settings can be selected by combining the three digital inputs as shown in
the table below.
Digital Inputs
Selected Speed
Multi-Speed
Reference 1
Multi-Speed
Reference 2
Multi-Speed
Reference 3
0
0
0
Speed Reference 1 (d1-01)
1
0
0
Speed Reference 1 (d1-02)
0
1
0
Speed Reference 1 (d1-03)
1
1
0
Speed Reference 1 (d1-04)
0
0
1
Speed Reference 1 (d1-05)
1
0
1
Speed Reference 1 (d1-06)
0
1
1
Speed Reference 1 (d1-07)
1
1
1
Speed Reference 1 (d1-08)
Separate Speed Inputs (d1-18=1 or 2)
Four different speed settings (defined in parameters d1-19, d1-20, d1-24, and d1-26) can be set and
selected using four digital inputs.
Speed Selection
Terminal
Details
H1-
**
=6
Nominal Speed
H1-
**
=9
Revision Speed
H1-
**
=7
Intermediate Speed
H1-
**
=8
Leveling Speed
Higher Speed has Priority (d1-18 = 1) (Default)
The higher speed has priority over the leveling speed. The leveling signal is disregarded as long as
any other speed selection input is active. The drive decelerates to the leveling speed (d1-26) when the
selected speed reference signal is removed.
Figure 3.1 elevator ride sequence when d1-18=1
Leveling Speed has Priority (d1-18 = 2)
The leveling signal has priority over other speed references. The drive decelerates to the leveling
speed (d1-26) when the leveling speed selection input is activated. The drive stops when either the
leveling input or the Up/Down command is released.