23
■
E2-11: Motor Rated Power
Sets the motor rated power in kW. If Auto-Tuning completes successfully, the value entered to T1-02
will automatically be saved to E2-11.
No.
Parameter Name
Setting Range
Default
E2-11
Motor Rated Power
0.00 to 8.25 kW
5.5 kW
H: Terminal Functions
H parameters are used to assign functions to the external terminals.
H1: Multi-Function Digital Inputs
■H1-03 to H1-06: Functions for Terminals S3 to S6
These parameters assign functions to the multi-function digital inputs. The various functions and
settings are listed in the table below.
No.
Parameter Name
Setting Range
Default
H1-03
Multi-Function Digital Input Terminal S3
Function Selection
0 to 14
6
H1-04
Multi-Function Digital Input Terminal S4
Function Selection
0 to 14
9
H1-05
Multi-Function Digital Input Terminal S5
Function Selection
0 to 14
7
H1-06
Multi-Function Digital Input Terminal S6
Function Selection
0 to 14
8
Setting
Function
0
Multi-Speed Reference 1
1
Multi-Speed Reference 2
2
Multi-Speed Reference 3
6
Nominal Speed
7
Intermediate Speed
8
Leveling Speed
9
Inspection Operation
11
Baseblock Command (N.O.)
12
Baseblock Command (N.C.)
13
Fault Reset
14
External Fault
Setting 0 to 2: Multi-Step Speed Reference 1 to 3
By setting three of the digital inputs to 1 to 3, 8 reference speeds set at d1-01 through d1-08 can be
accessed. Refer to d1: Frequency Reference for more details
.
Setting 6: Nominal Speed
Closing a terminal set for “Nominal speed” makes the drive run at the speed reference set to d1-19.
Conditions change, however, according to the speed selection mode set in d1-18.
Setting 7: Intermediate Speed
Closing a terminal set for “Intermediate speed” makes the drive run at the speed reference set to d1-
20. Conditions change, however, according to the speed selection mode set in d1-18.