![Saxun Bioclimatic Pergola P-150 Assembly Instructions Manual Download Page 21](http://html1.mh-extra.com/html/saxun/bioclimatic-pergola-p-150/bioclimatic-pergola-p-150_assembly-instructions-manual_1204931021.webp)
ASSEMBLY INSTRUCTIONS
4 COLUMNS DUPLEX P-150
19
02
ELECTRICAL CONNECTIONS
The connection of the electrical installation must be in compliance with the rules and regulations of each country (Low
voltage electrotechnical regulation).
The perimeter cabling for the electrical and sound installations will be passed through the beam and column spaces,
install the watertight cabinet on the outside in order to connect the power supply, so the pergola will only be able to reach
a voltage of 24 V.
The pergola controller can be installed on the closing beam, near the
column used to carry the LED, motor and power supply cables, so
they can be easily connected (all voltage 24V). Connect the sensors
to the side of the controller.
Use the beam and column caps for the cable insertions and exits
required for the installation.
Complete the electric connections of the pergola according to the
instructions and considering that both the motor and the LEDs run
with a 24 V voltage. For this reason, it is necessary to use the power
source, (installed at the end of the pergola).
For cables entering the switchboard:
- Cut the central part of the membrane.
- Insert the cable carefully to prevent any
water filtration.
ATTENTION:
For greater safety, it is necessary to ground the pergola.
Continue mounting the slats and transmission plates until completing the last slat, the opening one.
SENSORS