PARAMETER
DESCRIPTION
Temperature
This menu is used to measure the temperature of the sending water and/or the return water using a thermocouple K
contact probe connected to input T1 (OPTIONAL).
Then, by the function
Δ
T it is possible to calculate the relative temperature difference between the two
measurements.
Pressure
Thanks to the external RAUCLAIR tube supplied, it is possible, by connecting to the P+ input, to measure the
pressure within the limits indicated in the technical specifications. The pressure measurement has a HOLD function
that allows you to set the measured value on the display by pressing the Confirm key.
Leak detector
THIS MENU IS AVAILABLE ONLY IF THE SENSOR FOR COMBUSTIBLE GAS LEAKAGE IS INSTALLED ON
THE INSTRUMENT.
This allows fuel gas leaks to be found in the systems, both in piping and in appliances. To perform the test, the
installation of the internal semiconductor sensor for fuel gas leakage is required, as well as a probe equipped with
flexible tubing and a metal plunger that allows the gas to be taken on an ad hoc basis, even in areas with very low
leakage.
The sensor detects CH4 (Methane), LPG (Isobutane and Isopropane) but also other combustible gases
(Hydrocarbons).
Aux.
measurement
Through this menu the user can access other measurements.
Aux.meas.