![sauermann SI-CA 320 User Manual Download Page 66](http://html1.mh-extra.com/html/sauermann/si-ca-320/si-ca-320_user-manual_1202709066.webp)
66
10.3
Memory Menu
→
Save
15/01/14
10:00
Manual analysis mode
Number of selected memory
Number of analyses carried out
Memory
Save
Mode
Data logger
Memory
1
Samples
3
Analysis mode Data logger
Selected memory number
Number of samples to be taken
Interval
120
Interval between the samples
Analysis mode Confirmation of entry.
Number selected memory
KEY
FUNCTION
Enables the displayed interactive operations.
Starts recording the Flue gas analysis in the mode programmed for the "Data
logger" parameter.
Return to the previous page.
CONTEXT KEY
FUNCTION
OK
Starts recording the Flue gas analysis in the mode programmed for the "Data
logger" parameter.
F1
Deletes the contents of the selected memory.
(Visible if the selected memory contains previous analyses).
F2
Cancels the deletion of the contents of the selected memory.
(Visible if the selected memory contains previous analyses).
15/01/14
10:00
Memory
Save
Mode
Memory
Analysis
manual
1
1
OK
15/01/14
10:00
Memory
Save
Mode
Confirmation of entry
Memory
1
OK
OK