Section 3: Operation and Configuration
Page 3-32
CW408 Operator Manual
3.14 TEST PRINT MODE (Cont’d)
Printed Item Name
Item Name
Description
Factory TearOff
Tear off position adjustment
value for factory setting
±xx(dot)
Factory ALF
ALF position adjustment value
for factory setting
±xx(dot)
Sensor Type
Sensor type
Printing the selected sensor type.
I-mark: Reflective sensor
Gap: Transmissive sensor
Option Unit
Installed option
Cutter/ Dispenser/ None
Sensor1
Sensor type
Reflective, Transmissive
Low [Lo<0.6]/
High [0.9<Hi-Lo]/
Slice Level
Adjust Level(Emit)
Adjust Level(Recv)
Sensor level
The sensor level selected by the sensor type will be
shown.
1. When the sensor is disabled, Low/High will be
indicated as “None”.
2. When the slice level is automatic, it will be indi-
cated as “Auto”.
3. When the slice level is not automatic, Low/High
will be indicated as “----”.
4. When Low/High levels are outside the specified
range, they will be highlighted.
Sensor2
Sensor type
Paper Check
Slice Level
Adjust Level(Recv)
Sensor level
The sensor level selected by the sensor type will be
shown.
1. When the slice level is automatic, it will be indi-
cated as “Auto”.
Preliminary