Section 8: Appendix
CW408 Operator Manual
Page 8-5
8.4 BASE REFERENCE POINT ADJUSTMENT
8.4.1 Adjustment of Base Reference Point for Printing (Print Position)
Print position is adjustable within the range of +3.75 mm to -3.75 mm (+0.15” to -0.15”) using the adjustment
LCD setting described above. The shift experienced by the media or print layout can be offset with the
adjustment of the pitch position.
Note:
The above base reference point for printing is the stop position when sensor type is set to Gap sensor.
Adjustment Location
Adjustment Range
Adjustment mode: Pitch position
+3.75 mm to -3.75 mm
(+0.15” to -0.15”)
-3.75 mm (-0.15”)
Media feed direction
Base reference
point for printing
(Print head)
Adjustment for
“+” value
No
Adjustment
Adjustment for
“-” value
Gap
+3.75 mm (+0.15”)
43.91 mm (1.73”)