Explanations for Fig. 1: 
1 – 

LED indicators: 

PWR

 – 

power indicator

 – ON when power supply is connected 

ST

 – 

status indicator:

 

  ON – RS-232 port working in RC4000 VISONIC, SurGuard (MLR2/MLR2E) 

or RSM-02 receiver emulation mode  

  blinking fast – replacement of converter firmware 

  momentarily dimming – wrong converter configuration data (also on the 

first-time run, before configuration) 

  lights up momentarily – RS-232 port available for communication with the 

computer  

RI

 – 

ringing indicator

 – ON when the converter is calling the reporting station 

OH

 – 

reporting station connection

 

indicator:

 

  ON – connection to the monitoring station 

  blinking – timeout of reporting station connection (converter is sending no 

more data) 

WT

 – 

handshake / kiss-off indicator:

 

  ON – waiting for handshake / kiss-off signal from the monitoring station 

  blinking – there are data to be sent, but there is no kiss-off signal from the 

monitoring station 

ERR

 – 

trouble

 

indicator:

 

  blinking fast – no Ethernet network cable 

  1 short blink, followed by a pause – the station is not answering the call 

  2 short blinks, followed by a pause – the station went off-hook, but no 

handshake / kiss-off signal was received 

  3 short blinks, followed by a pause – the station hung up before all data were 

sent 

2 - 

RJ-45 socket

 for connection of the Ethernet network cable. Use the same cable as the 

one for connecting computer to the network. The socket has two built-in indicator LEDs. 
The green one indicates connection to the network and data transfer, and the yellow 
one – negotiated transmission rate (ON: 100Mb; OFF: 10Mb). 

3 - 

RJ socket 

(6P2C) for connection of the telephone cable, connecting the converter to 

the monitoring station. 

4 - 

power socket

 for connection of the 12 V DC power supply unit 

. The power 

supply current capacity must be at least 

750 mA

5 - 

DB-9F socket (RS-232 port)

 for communication with the reporting station (emulation of 

RC4000 VISONIC, SurGuard (MLR2/MLR2E) and RSM-02 receiver) or the computer. 

3. C

ONVERTER INSTALLATION

 

1.  Connect the Ethernet network cable to the RJ-45 socket. 
2. Using telephone cable, connect the converter RJ socket with the reporting station 

(emulation of analog telephone line), or connect the converter DB-9 socket with the 
reporting station RS-232 port (emulation of RC4000 VISONIC, SurGuard (MLR2/MLR2E) 
and RSM-02 receiver). 

3.  Connect power supply. 

Summary of Contents for SMET-256

Page 1: ...CONVERTER FOR MONITORING STATION SMET 256 USER MANUAL Program version v1 07 smet256_en 04 11...

Page 2: ...y improve the quality of its products which may lead to alterations in their technical specifications and firmware Current information on the introduced modifications is available on our website Pleas...

Page 3: ...Support of up to 256 subscribers in the extended mode with control of communication with the subscriber Support of unlimited number of subscribers in the simple mode without control of communication...

Page 4: ...blinks followed by a pause the station went off hook but no handshake kiss off signal was received 3 short blinks followed by a pause the station hung up before all data were sent 2 RJ 45 socket for c...

Page 5: ...ith the device must be installed on the computer Additionally the CD includes an installer for the SMET 256 Soft program 4 1 WEB BROWSER 1 Start the web browser 2 Enter the IP address of the converter...

Page 6: ...the subscribers 6 Save the data to the converter 4 2 2 Configuration through TCP IP network Note Before you proceed to programming through the TCP IP network the converter must be configured by means...

Page 7: ...Using the digit 0 in the identifier is not recommended ETHM GPRS key enter in this field a sequence of 1 to 5 alphanumeric characters identifying the device provided with reporting function alarm cont...

Page 8: ...6 SMET 256 SATEL Fig 4 The Subscribers tab in web browser with some examples of subscriber definitions the window available in SMET 256 Soft program differs only in graphic details...

Page 9: ...if communication is lost Restore E code denoting restoration of communication with the device sending data through the TCP IP network if the Normal format has been selected enter in this field 2 char...

Page 10: ...d with reporting function alarm control panel GSM module Click the right hand button on your mouse to display the menu with the following functions Add based on the transmission selected a new subscri...

Page 11: ...t mask mask of the subnetwork in which the converter works The field is available when the Static IP field has been enabled Default gateway network gateway i e IP address of the network device through...

Page 12: ...USA by the United States rules by date 1 hour 1 hour correction according to dates by date 2 hours 2 hour correction according to dates Summer time since the field is available when the clock settings...

Page 13: ...port tab Fig 7 The RS port tab Configuration window in the web browser the window available in the SMET 256 Soft program differs only in graphic details The settings in the tab apply to communication...

Page 14: ...determine the key for data coding during communication The identical server key must be entered in the settings for monitoring the subscriber s device By default abcde Port in this field enter the nu...

Page 15: ...SONIC RC4000 SurGuard MLR2 MLR2E RSM 02 Buzzer check this box if receiving a transmission by the converter is to be audibly signaled Conversion A 0 Parameters defined in this area apply to all events...

Page 16: ...o 25 can be entered By default 10 Code list the list is displayed if the SurGuard MLR2 MLR2E format has been selected It enables the event type to be defined depending on the first character of event...

Page 17: ...rs defined in this area will restore the converter factory settings Configuration when you select this box and click on the Restore values button all parameters and settings in the Configuration windo...

Page 18: ...er message will be displayed Buffer event size Parameters defined in this area are used for configuring the memory of events It is possible to determine the number of bytes of received events after re...

Page 19: ...s displayed in the SMET 256 Soft program There are two graphic styles available in the program i e BusinessBlackSteel and Windows For the changes to take effect select the appropriate field click on t...

Page 20: ...SATEL sp z o o ul Schuberta 79 80 172 Gda sk POLAND tel 48 58 320 94 00 info satel pl www satel pl...

Reviews: