14 SMET-256
SATEL
Receiver No. [1-9]
– the field is available, if the SurGuard (MLR2/MLR2E) format has
been selected. Enter in it the number of receiver the data transfer from which is
simulated by the converter. Values from 1 to 9 can be entered. By default: 1.
Line No. [1-9]
– the field is available, if the VISONIC (RC4000) format has been
selected. Enter in it the number of line the data transfer from which is simulated by
the converter. By default: 1.
Line No. [1-99]
– the field is available, if the SurGuard format has been selected. If the
number is between 1-9, then the SurGuard MLR2 format is chosen, if the number is
between 10-99, then the SurGuard MLR2E format is chosen. Enter in it the number
of line the data transfer from which is simulated by the converter. By default: 1.
Test period [0-255]
– the field is available, if the SurGuard (MLR2/MLR2E) format has
been selected. This parameter is used for the control of communication with
monitoring station. The time is to be defined in seconds. Values from 0 to 25 can be
entered. By default: 10.
Code list
– the list is displayed, if the SurGuard (MLR2/MLR2E) format has been
selected. It enables the event type to be defined, depending on the first character of
event code.
Test transmissions
– the field is available, if the RSM-02 has been selected. Select
this field to activate the function of testing connection between the converter and the
monitoring station. By default: selected.
"Login details" tab
Fig. 9. The "Login details" tab, "Configuration" window in the web browser (the window
available in the SMET-256 Soft program differs only in graphic details).
Enabled
– select this box to enable the device to be configured in the web browser. At the
same time it will activate all the fields relating to login via the web browser.
User
– user name. It is required to log in to the device configuration in the web browser. By
default: satel.
Password
– user code. It is required to log in to the device configuration in the web browser.
By default: satel.
Port
– in this field, enter the number of network port to be used for communication with the
computer. Values from 1 to 65535 can be entered. The value must be different from that
entered for the other ports. By default: 22222.