SATEL SMET-256
13
during communication. The identical server key must be entered in the settings for
monitoring the subscriber's device. By default: edcba.
Port
– the field is available, if the “Enabled” box is checked. Enter in this field the
number of network port to be used for communication. Values from 1 to 65535 can
be entered. The value must be different from that entered for the other ports. The
identical port number must be entered in the settings for monitoring the subscriber's
device. By default: 54321.
Note:
In the case of the simple mode, the SMET-256 converter version 1.07 or higher,
after receiving every event, will check whether the subscriber from which the
event has been received, is on the list of subscribers assigned to the extended
mode. If the subscriber is present on the list, the converter will extend the time
of communication with the given subscriber.
Formats
Parameters defined in this area apply to the method of transmitting data to the
monitoring station.
Outgoing format
– in this field, define the output format of data to be sent to the
monitoring station. One of the following formats can be selected:
– Phone [default setting]
– VISONIC
(RC4000)
– SurGuard
(MLR2/MLR2E)
– RSM-02
Buzzer
– check this box if receiving a transmission by the converter is to be audibly
signaled.
Conversion (A>0)
Parameters defined in this area apply to all events sent to the monitoring stations,
except for the SIA format.
Ident.
– select this field, if the letter A in the identifier of event sent to the monitoring
station is to be changed to the digit 0, so that the station can decode it properly.
Event
– select this field, if the letter A in the code of event sent to the monitoring station
is to be changed to the digit 0, so that the station can decode it properly.
Format
– this field is available, if "Phone" has been selected in the "Outgoing format"
field. It allows you to select one of the telephone monitoring formats in which events
will be sent to the monitoring station. The following formats are available:
– Ademco
slow
– Sescoa, Franklin, DCI, Vertex
– Silent Knight fast
– Radionics
1400
– Radionics
2300
– Radionics 1400 with parity
– Radionics 2300 with parity
– Ademco
Express
Note:
Events received in the Contact ID format or SIA are sent to the reporting
station in the same format.
Receiver No. [1-99]
– the field is available, if the VISONIC (RC4000) or RSM-02 format
has been selected. Enter in it the number of receiver the data transfer from which is
simulated by the converter. Values from 1 to 99 can be entered. By default: 1.