8
Step #1:
Carefully remove the cover using two flat screwdriver as shown.
Operator Housing Removal
PULL Application Mounting Plate Hole Locations
Opening Angle Max. 100°
2660 Shown
Step #2:
Drill and tap four #12 holes with a #12 x 24 tap and mount the mounting plate to the door frame using
four #12 x 24 flat head screws. The conduit end of the mounting plate is to be positioned near the hinge side of the
frame.
Step #3:
Drill and tap (two places) door arm foot or slide track holes with a #7 drill. Tap holes 12 x 24.
PULL Type Arm Application
7-1/8"
21-1/8"
1-1/8"
TOP OF
DOOR
C OF PIVOT
L
PULL TYPE APPLICATION
INSTALLATION INSTRUCTIONS
7-7/8"
2-3/32"
2-7/16"
3-3/8"
3/4"
FROM TOP
OF FRAME
TOP OF
DOOR
22-7/8"
4-1/2"
7-1/4"
2"
2-1/2"
C OF PIVOT
L