11
INITIAL ELECTRICAL CONNECTIONS
Power Requirements:
115 VAC, 15 Amp service for one or two operators. Use a dedicated 20 Amp service for three or four operators.
•
Be sure main breaker is disconnected
•
Remove cover from terminal block
•
Attach GROUND, NEUTRAL, and LINE voltage wires to terminal block
Step #1:
Make electrical connections to the operator.
Step #2:
Make electrical connections, connect external fire alarm system.
Note: Remove factory installed jumper when connecting to a remote fire alarm system.
Fire adapter is factory configured for Normally Closed fire alarm contacts.
TERMINAL
BLOCK COVER
GREY
BROWN
BROWN
CHASSIS
GROUND
GREEN/YELLOW
115V
230V
LINE
INPUT
SETTING
LINE
NEUTRAL
GROUND
POWER
SWITCH
FACTORY WIRED FOR 120 VOLTS
FUSE
T 800mA
1
2
3
4
5
6
7
8
9
NO
C
NO
C
POWER ALARM
BATTERY ALARM
INTERNAL
CONNECTIONS
FIRE ADAPTER
N.C. REMOTE
FIRE ALARM
CONTACT
WARNING:
Electrical connections should
be made by a qualified electrician.