5
Step #2:
Drill and tap four #12 holes with a #12 x 24 tap and mount the mounting plate to the door frame
using four #12 x 24 flat head screws. The conduit end of the mounting plate is to be positioned near the hinge
side of the frame.
Step #1:
Carefully remove the cover using two flat screwdriver as shown.
Operator Housing Removal
PUSH Application Mounting
Plate Hole Locations
7-7/8"
2-3/32"
2-7/16"
3-3/8"
3/4"
FROM TOP
OF FRAME
TOP OF
DOOR
22-7/8"
4-1/2"
7-1/4"
2"
2-1/2"
C OF PIVOT
L
Opening Angle Max. 100°
2651/2652 Shown
PUSH TYPE APPLICATION
INSTALLATION INSTRUCTIONS
Step #3:
Drill and tap (two places) door arm foot or slide track holes with a #7 drill. Tap holes 12 x 24.
PUSH Type Arm Application
13-1/16"
1-3/4"
TOP OF
DOOR
DIM. "A"
C OF PIVOT
L
DIM “A”
SPINDLE
EXTENSION
1-9/16"
—
—
1-15/16"
63-0603
2-3/8"
63-0604
3-15/16"
63-0605