6
Step #4:
Pull conduit and external
component wires through frame and cutout
in mounting plate. Allow at least 10 inches
of exposed wire for electrical connections.
CONDUIT
FRAME
DOOR
WALL
WHITE (+)
BLACK (–)
GREEN (GND)
END OF CONDUIT MUST
NOT PROTRUDE PAST
THE SURFACE
MOUNTING
PLATE
WARNING: Ensure that 115VAC
power is OFF before touching wires.
Step #5:
Mount the door operator to the mounting plate with four M8x25 screws and washers provided.
Note: Mount the operator with the power switch end cap toward the door hinge.
MOUNTING
PLATE
DOOR
FRAME
DOOR
OPERATOR
PUSH ARM
EXTENSION ARM
DOOR ARM FOOT
PUSH TYPE APPLICATIONS
INSTALLATION INSTRUCTIONS