SECTION 3
17
SAPPHIRE SCIENTIFIC MODEL 370 SS
®
PART#
49-038 REV F
CHEMICAL PUMPING SYSTEM
The chemicals are drawn from the chemical
container through a strainer into the flow meter
mounted on the control panel. The flow meter
indicates the rate of chemical flow.
The chemicals then flow through the stainless
steel chemical pump and are injected into a
three way selector valve located on the front
panel. This valve may be used to turn the
chemical flow
ON
,
OFF
, or to
PRIME
the
chemical pump.
The chemicals then flow through the chemical
metering valve to the solution outlet. This valve
controls the rate of flow of chemical into the
cleaning solution, which is indicated on the flow
meter.
Water Pump
Solution
Outlet
Solution
Outlet
Manifold
Chemical
Metering
Valve
3 Way
Select
Valve
Flow Meter
Chemical Supply Line
Chemical Prime Line
Chemical Pump