SY6600 Vector Control Inverter User Manual
84
P7.07 Frequency corresponding to P7.06 0.00 ~ Maximum frequency
P7.08 Maximum AI2
0.0-100.0%
P7.09 Frequency corresponding to P7.09 0.00 ~ Maximum frequency
Reference signal from external input (AI1, AI2) is filtered and amplified, and
then its relationship with frequency setting is shown as curve 1 in Fig. 6-25 or curve
2 in Fig.6-26.
AI2 can input current signal (4~20mA), P7.06 should be set to 20% except that
S1 (AI2) is in “I” position,
P7.10 FWD/REV dead time range Setting range: 0~10% Maximum input signal
If polarity control is selected (P0.06= 2 or 3), FWD/REV dead time is set by
this parameter. Refer to parameter P0.06 and fig 6-1 for details.
P7.11 AI0 filter time
Setting range: 0.05-5.00S
P7.12 Minimum AI0
0.0-100.0%
P7.13 Frequency corresponding toP7.12
0.00 ~ Maximum frequency
P7.14 Maximum AI0
0.0-100.0%
P7.15 Frequency corresponding to P7.13 0.00 ~ Maximum frequency
Reference signal(AI1) from keypad potentiometer is filtered and amplified, and
then its relationship with frequency setting is shown as curve 1 in Fig. 6-25 or curve
2 in Fig. 6-26.