3-2
ELECTRICAL ADJUSTMENT PROCEDURES
1. Servo Adjustment
1) PG Adjustment
• Test Equipment
• Adjustment And Specification
a) OSCILLOSCOPE
b) PAL TEST TAPE (VHS SP)
c) JIG REMOCON (AUTO PG SETTING)
MODE
PLAY
• Adjustment Procedure
a) Insert the PAL SP Test Tape and play.
Note - Adjust the distance of X, pressing the Tr) or Tracking(-) when the “ATR(OSD on moni-
tor)” is blink after PAL SP test Tape is inserted.
b) Press
Front
“Play” key on set and “0” key on
Remocon.(Then check the light
all CLK/DOT LED on CLK/LED -TRK
is a Initial)
c) press
Front
“Play” key on set and “0” key on
Remocon again.(Then check the blink
"OFF->ON" on CLK/LED,
Then check blink “PG
waveform” on oscilloscope
.
• Check the PG
a) Connect the CH1 of the oscilloscope to the H/SW and CD2 to the Video out for the VCR.
b) Trigger the mixed Video Signal of CH2 to the CH1 H/SW(W501, W502), and then check the distance
(time difference), which is from the selected A(B) Head point of the H/SW(W501, W502) signal to the
starting point of the vertical synchronized signal, to 6.5H ± 0.5H (416µs, 1H=64.0µs).
• CONNECTION
V.Out
H/SW(W501, W502)
6.5 ± 0.5H
MEASUREMENT POINT
ADJUSTMENT POINT
SPECIFICATION
V.Out
H/SW(W501,W502)
OSCILLOSCOPE
CH1 CH2
V.out
H/SW
(W501, W502)
Summary of Contents for VHR-H772EV
Page 11: ......
Page 15: ......
Page 57: ...MAINTENANCE INSPECTION PROCEDURE 4 22 GEAR F R GEAR AY P2 P3 Lever F R Base Tension Boss Cam ...
Page 90: ...MEMO ...
Page 91: ...SANYO Electric Co Ltd Osaka Japan Jun 02 K Printed in Japan ...