34
10. FUNCTIONS
10-1. Functions for Operation
10-1-1. Operation Selector
(1) OFF :
●
Used when the remote control unit is not available
(Self-Diagnosis)
●
Used for servicing and maintenance
(2) ON:
●
Normal operation...............Operate using remote control unit
●
Emergency operation ........Used when the remote control unit is not available. When ON
position is selected, the air conditioner starts operating with
cooling mode.
(3) TEST:
●
Used to confirm operational characteristics
●
Used for pump-down
(The unit operates at nominal frequency. In this case, a lamp on the unit will flash and it
will not accept signals from the remote control unit.)
(4) DEMO:
●
Used for demonstration at shopfronts; not for normal use
●
Used for service
10-1-2. Automatic Operation
In Automatic Operation, indoor and outdoor temperature sensors operate and either Dry or Cooling Operation is
selected automatically. Refer to the Instruction Manual (p.13).
10-1-3. Display on the Main Unit <SAP-KMV91G and SAP-KMV181G>
Operation Lamp....................green/red
Timer ..............................green
Service Lamp .......................green
The service lamp illuminates only when the self-diagnosis function is used for servicing.
Selection of Operation Mode
Outdoor temperature
Approx. 22
¡
C
Approx. 20
¡
C
Drying
operation
Temperature when
operation starts
(20
¡
C to 26
¡
C)
Temperature setting
(standard)
Indoor temperature
Cooling operation
27
¡
C
Approx.
15
¡
C
Approx.
22
¡
C
Approx.
27
¡
C
OPERATION
TIMER
OPERATION lamp
TIMER lamp
Service lamp