7-3. Performance Charts
230V, 50Hz
Indoor unit
SAP-KMV91G
Outdoor unit
SAP-CMV2441G
25
30
35
40
45
50
10
32
27
21
9
8
7
6
5
4
3
2
1
Operating current (A)
Outdoor inlet air D.B. temp.(˚C)
Indoor inlet air
D.B. temp. (˚C)
25
30
35
40
45
50
1.4 (13)
32
27
21
1.3 (12)
1.2 (11)
1.1 (10)
1.0 (9)
0.9 (8)
0.8 (7)
0.7 (6)
0.6 (5)
0.5 (4)
0.4 (3)
Low pressure at wide tube service valve MPa (kgf/cm
2
G)
Outdoor inlet air D.B. temp.(˚C)
Indoor inlet air
D.B. temp. (˚C)
■
Cooling Characteristics
Indoor unit
SAP-KMV181G
Outdoor unit
SAP-CMV2441G
25
30
35
40
45
50
14
32
27
21
13
12
11
10
9
8
7
6
5
Operating current (A)
Outdoor inlet air D.B. temp.(˚C)
Indoor inlet air
D.B. temp. (˚C)
25
30
35
40
45
50
32
27
21
Low pressure at wide tube service valve MPa (kgf/cm
2
G)
Outdoor inlet air D.B. temp.(˚C)
Indoor inlet air
D.B. temp. (˚C)
■
Cooling Characteristics
1.4 (13)
1.3 (12)
1.2 (11)
1.1 (10)
1.0 (9)
0.9 (8)
0.8 (7)
0.7 (6)
0.6 (5)
0.5 (4)
0.4 (3)
●
…
Points of rating condition
Black dots in above charts indicate the following rating conditions.
Cooling: Indoor air temperature 27°C D.B. / 19°C W.B.
Outdoor air temperature 35°C D.B. / 24°C W.B.
NOTE