Troubleshooting
temperature monitor operation
The temperature monitor system is provided to prevents
damage of optical components (the LCD panel and po-
larization film etc.) inside a projector from overheat.
Two protection systems are provided. Each system op-
eration as follows :
the temperature monitor -1:
●
to control the air-flow of the cooling fans.
The CPU checks the temperature and atmospheric
pressure inside a projector. It checks a temperature
using temperature sensors IC541 and IC8811, and it
checks an atmospheric pressure using pressure sen-
sor-IC886. The CPU judges data from sensors and
controls the air flow of the cooling fans so the tem-
perature inside the projector is maintained to normal
temperature.
●
to shut down the projector urgently.
The CPU checks temperature of LCD panel periphery
(TH901) and intake air (IC8811). If each part tempera-
ture reaches abnormal temperature, the CPU will turn
off the projector, and will blink WARNING TEMP. in-
dicator at intervals of 0.5 seconds. Cooling fans oper-
ate until temperature returns to normal. Indicator will
stop blink, if temperature returns to normal.
the temperature monitor -2 :
●
temperature check of lamps :
Temperature switches (SW903, SW904) are placed
near the lamps. Temperature switches will operate,
if temperature reaches 90 ºC. When temperature
switches become open, they cut off 1VA line, the
power failure "PF_TH" signal become Low, and then
the CPU will shut down the projector, and the LAMP
indicator is lighting and other indicators are blinking.
NOTE : SENSORS OPERATION
■
The sensor's operation is as follows:
IC886
: For FAN control
TH901
: Abnormal temperature detection
IC2541
: Inside air temperature monitor
IC8801
: Abnormal temperature detection and
for FAN control
LED indicators
When the internal temp
error, the WARNING TEMP.
indicator will be blinking.
When the temperature rises
abnor mally around the
lamps1 or 2, the LAMP indi-
cator is lighting and other
indicators are blinking.
The temperature
switch is operated?
If the temperature
around FET reaches 85
degrees, a PFC circuit
will be shut down.
The temperature switch is
operated?
When the temperature
around a lamp driver reach-
es 85 degrees, the lamp bal-
last will be shut down and
a lamp error signal changes
from L to H.
Temperature sensors location can be seen on
"protections"( page-8).
Temperature Abnormality
IC801
CPU
R/C
FAN
FAN
POWER
POWER(DC)
NOISE
FILTER
AC
INPUT
BALLAST
1/2
P.F.C.
1/2
LAMP-1/2
TH901
TEMP. SENSOR
IC2541
TEMP. SENSOR
IC8801
TEMP. SENSOR
IC886
PRESSURE SENSOR
INDICATORS
FAN
CONTROL
FAN
CONTROL
RESET KEY
SW902
LAMP COVER SW
DA
CONVERTER
SW903/904
THERMAL SW
MAINS
SW
FUSE
SWITCHING
POWER
SUPPLY
PRIMARY CIRCUIT
PF_
FANS
POWER
FAIL
POWER
FAIL
12VA
12V
PF_TH
LAMP3/4
PF_PFC3/4
IC_RESET_CPU
BLAST_SW3/4
IIC
IC5801
IO
IC1881
Check FAN
circuits.
Check the
temperature
switches.
Summary of Contents for PLV-WF20
Page 164: ... 164 Parts Location Diagrams KY3 WF2000 MIrror R Assembly S06 L13 Relay In Assembly L11 ...
Page 166: ... 166 Parts Location Diagrams KY3 WF2000 L15 L12 L16 In the Optical Lamp Unit ...
Page 211: ...Key No Part No Description Key No Part No Description KY3 WF2000 211 Electrical Parts List ...
Page 212: ... KY3A Feb 2008 DC 300 Printed in Japan SANYO Electric Co Ltd ...