-141-
Status Read Command
The command is sent from PC to the projector with the
format below;
'CR' [Command] 'CR'
Command: one character (refer to the command table
below.
The projector decodes the command and returns the
'Character string' with the format below;
Format
command
Function
Projector
return
Projector status
CR0
Status Read
00
Power On
80
Stand-by mode
40
Countdown
0
Cooling down
10
Power Malfunction
8
Cooling down at the temperature anomaly
0
Unable to receive the RC3C command.
4
Cooling down at Power Management mode
04
Power Management mode after Cooling down
1
Cooling down after the projector is turned off when the lamps
are out.
81
Stand-by mode after Cooling down when the lamps are out.
88
Stand-by mode after Cooling down at the temperature
anomaly.
C
Cooling down when the projector is turned off by the shutter
management function.
8C
Stand-by mode after Cooling down by the shutter management
function.
CR6
Temperature Read
S1 S S3
S1 = Temperature at Sensor 1 (˚C)
S = Temperature at Sensor (˚C)
S3 = Temperature at Sensor 3 (˚C)
(ex.) S1 = 1.3˚C, S = 3.4˚C, S3 = 34.5˚C
--> The projector displays “1.3 3.4 34.5”
( For each sensor, two digit and the tenth place numbers are
displayed with a space between each temperature.)
?
Communication failure
The tables on page 140 and 141 show the typical command lists for controlling the projector. Please consult your
local dealer for further information of other commands.
Serial Control
Summary of Contents for PLV-WF20
Page 164: ... 164 Parts Location Diagrams KY3 WF2000 MIrror R Assembly S06 L13 Relay In Assembly L11 ...
Page 166: ... 166 Parts Location Diagrams KY3 WF2000 L15 L12 L16 In the Optical Lamp Unit ...
Page 211: ...Key No Part No Description Key No Part No Description KY3 WF2000 211 Electrical Parts List ...
Page 212: ... KY3A Feb 2008 DC 300 Printed in Japan SANYO Electric Co Ltd ...