-43-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
range Note
8 DIMMER_CTRL_LEVEL9
Luminance Level 9 Data for Dimmer:
Dim Level 9 at the less than the
Value
63
0-55
9 DIMMER_CTRL_LEVEL10
Luminance Level 10 Data for
Dimmer: Dim Level 10 at the less
than the Value
70
0-55
10 DIMMER_CTRL_LEVEL11
Luminance Level 11 Data for
Dimmer: Dim Level 11 at the less
than the Value
77
0 - 55
11 DIMMER_CTRL_LEVEL1
Luminance Level 1 Data for
Dimmer: Dim Level 1 at the less
than the Value
84
0 - 55
1 DIMMER_CTRL_LEVEL13
Luminance Level 13 Data for
Dimmer: Dim Level 13 at the less
than the Value
91
0 - 55
13 DIMMER_CTRL_LEVEL14
Luminance Level 14 Data for
Dimmer: Dim Level 14 at the less
than the Value
98
0 - 55
14 DIMMER_CTRL_LEVEL15
Luminance Level 15 Data for
Dimmer: Dim Level 15 at the less
than the Value
105
0 - 55
15
DIMMER_AVERAGE_POINT
Luminance Data Avarage Point for
Mimmer
4
0 - 16
16 DIMMER_AVERAGE_DATA
Luminance Data Avarage Value for
Dimmer
-
-
* Read only
17 DIMMER_LEVEL_AUTO
Current Dimmer Leverl
-
-
* Read only
18 DIMMER_LEVEL_NORMAL Normal Dimmer Level
8
0 - 15
19 DIMMER_LEVEL_ECO
Eco Dimmer Level
0
0 - 15
0 Lamp check enable
0
0: Lamp Failure Detection OFF
(White 50% Back), 1 : ON (Blue
100% Back)
1 VOLTAGE_LEVEL
Lamp Voltage
-
Unit: 8bit(Raw Data) * Read only
DIMMER_LEVEL_HIGH
Dimmer level High
15
0 - 15
Group
231
VBI Slice level
0 Generic Initial Slicing Level
PW190 register 0xE344
0x34
0-55
1 Generic High Level Threshold PW190 register 0xE345
--
0-55
Generic Low Level Threshold PW190 register 0xE346
--
0-55
3 Generic Minimum Low Level PW190 register 0xE347
0x30
0-55
4 Generic Maximum High Level PW190 register 0xE348
0xe0
0-55
Group
250
FAN control
0 FAN1 MIN ADJUST (DAC)
DAC Output for Fan
Adjust the tolerance of DAC and Fan
Volage.
* Lamp mode is forced Eco
10
0 - 55
1 FAN1 MAX ADJUST (DAC)
5
0 - 55
FAN MIN ADJUST (DAC)
10
0 - 55
3 FAN MAX ADJUST (DAC)
5
0 - 55
4 FAN3 MIN ADJUST (DAC)
15
0-55
5 FAN3 MAX ADJUST (DAC)
55
0-55
6 Not used
7 Not used
Group
251
Not used
Group
252
Fan option
0 HI-LAND SWITCH
0: Normal, 1: Hi-Land, -4: Hi-Land
1-3
0
0 - 5
1 SAFETY SWITCH
For test purpose
0
0 - 6
FAN MANUAL SWITCH
0: Auto, 1: Manual
0
0 - 3
3 FAN1 MANUAL VOLTAGE
Fan Voltage (unit : 0.1V)
Effective only when Fan Manual
switch is 1
100
0 - 55
4 FAN MANUAL VOLTAGE
100
0 - 55
5 FAN3 MANUAL VOLTAGE
100
0 - 55
6 Not used
-
Group
253
Fan tem error Setting (Memorized)
Normal Ceiling HiLand-
Normal
HiLand-
Ceiling
5 Temp A Warning (Normal)
Temp. A to judge the Temp Error at
Normal (Room)
4
4
41
41
30-100
6 Temp B Warning (Normal)
Temp. B to judge the Temp Error at
Normal (Panel)
60
60
60
60
30-100
7 Temp C Warning (Normal)
Temp. C to judge the Temp Error at
Normal (Lamp)
60
60
60
60
30-100
8 Temp B-A Warning (Normal)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
Summary of Contents for PLC-XU301
Page 63: ... 63 IC Block Diagrams FA5550NG P F Control IC621 XR16L5701IL24 UART IC9885 ...
Page 67: ... 67 IC Block Diagrams MR4010 Power OSC IC631 PIC18F67J60 LAN CONTROL IC8801 ...
Page 68: ... 68 IC Block Diagrams FA7703 DC DC Converter IC7811 Sil9127 HDMI Receiver IC8001 ...
Page 95: ...KD5 XU30100 95 Mechanical Parts List ...
Page 96: ... KD5AC MAY 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Page 108: ...A10 SCH_KD5AC NO DATA ...
Page 112: ...A14 PCB_KD5AC NO DATA ...