-44-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
range Note
9 Temp C-A Warning(Normal)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
10 Temp A Warning (Eco)
Temp. A to judge the Temp Error at
Eco (Room)
4
4
41
41
30-100
11 Temp B Warning (Eco)
Temp. B to judge the Temp Error at
Eco(Panel)
58
58
58
58
30-100
1 Temp C Warning (Eco)
Temp. C to judge the Temp Error at
Eco(Panel)
60
60
60
60
30-100
13 Temp B-A Warning (Eco)
Temp. B-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at
Normal (Clogging Det.)
100
100
100
100
0-100
15 Temp A Warning Offset
(Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
16 Temp B Warning Offset
(Temp)
5
0-100
17 Temp C Warning Offset
(Temp)
5
0-100
18 Temp B-A Warning Offset
(Temp)
0
0-100
19 Temp C-A Warning Offset
(Temp)
0
0-100
0 Temp A Warning Offset
(Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X min-
ute at the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
3
0-100
1 Temp B Warning Offset
(Time)
3
0-100
Temp C Warning Offset
(Time)
3
0-100
3 Temp B-A Warning Offset
(Time)
3
0-100
4 Temp C-A Warning Offset
(Time)
3
0-100
Group
254
Fan control range Setting (temp./Voltage)
Normal Ceiling HiLand-
Normal
HiLand-
Ceiling
10 Normal Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Normal
33
33
33
33
0-100
11 Normal Fan Control Max
Temp
38
38
37
37
0-100
1 Normal Fan1 Min
Fan voltage value at Normal (unit:
0.1V)
75
80
90
90
0-55
13 Normal Fan1 Max
15
15
135
135
0-55
14 Normal Fan Min
68
75
80
80
0-55
15 Normal Fan Max
80
80
80
80
0-55
16 Normal Fan3 Min
80
85
90
90
0-55
17 Normal Fan3 Max
135
135
135
135
0-55
0 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p
at Eco
30
30
33
33
0-100
1 Eco Fan Control Max Temp
38
38
37
37
0-100
Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
55
60
80
80
0-55
3 Eco Fan1 Max
115
10
15
15
0-55
4 Eco Fan Min
45
45
55
55
0-55
5 Eco Fan Max
50
50
60
60
0-55
6 Eco Fan3 Min
70
75
80
80
0-55
7 Eco Fan3 Max
15
15
15
15
0-55
Group
255
Fan Start/cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
55
0-55
1 Fan Initial Volt
55
0-55
Fan3 Initial Volt
55
0-55
4 Fan1 Cooling Speed
Fan Voltage at Power Off (0.1V)
130
0-55
5 Fan Cooling Speed
130
0-55
6 Fan3 Cooling Spees
130
0-55
8 Cooling Time L1
Cooling Time stting at Fan Mode L1 (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
1-15
9 Cooling Time L
Cooling Time stting at Fan Mode L (x
30 sec)
1: 30, 3: 90, 15: 450 sec.
3
1-15
10 Temp Error Cooling Time
Cooling Time setting at Temp Erro (x
30 sec)
3
1-15
11 OnStart Cooling Start Thresh-
old
38
0-100
1 After shutdown cooling
Cooling after shutdown (0: No, 1: Yes)
1
0-1
Group
256
Fan lamp Voltage down Setting
0 Lamp Voltage
Current Lamp Voltage (0.1V)(Read
only)
-
0-55
Summary of Contents for PLC-XU301
Page 63: ... 63 IC Block Diagrams FA5550NG P F Control IC621 XR16L5701IL24 UART IC9885 ...
Page 67: ... 67 IC Block Diagrams MR4010 Power OSC IC631 PIC18F67J60 LAN CONTROL IC8801 ...
Page 68: ... 68 IC Block Diagrams FA7703 DC DC Converter IC7811 Sil9127 HDMI Receiver IC8001 ...
Page 95: ...KD5 XU30100 95 Mechanical Parts List ...
Page 96: ... KD5AC MAY 2009 DC 200 Printed in Japan SANYO Electric Co Ltd ...
Page 108: ...A10 SCH_KD5AC NO DATA ...
Page 112: ...A14 PCB_KD5AC NO DATA ...