-40-
Electrical Adjustments
Group/
Item
Item Name
Function
Initial
Range
Note
14 Temp C-A Warning (Eco)
Temp. C-A to judge the Temp Error at Normal
(Clogging Det.)
100
100
100
100
0-100
15 Temp A Warning Offset (Temp)
Offset of Temp Error (Temp.)
Error Setting Value is increased XC at the
below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
16 Temp B Warning Offset (Temp)
5
0-100
17 Temp C Warning Offset (Temp)
15
0-100
18 Temp B-A Warning Offset (Temp)
0
0-100
19 Temp C-A Warning Offset (Temp)
0
0-100
20 Temp A Warning Offset (Time)
Offset of Temp Error (Minutes)
Error Setting Value is increased X minute at
the below condition
* Standby
* Right to turn on the lamp
*Right to change the Lamp mode
5
0-100
21 Temp B Warning Offset (Time)
5
0-100
22 Temp C Warning Offset (Time)
18
0-100
23 Temp B-A Warning Offset (Time)
1
0-100
24 Temp C-A Warning Offset (Time)
1
0-100
25 Factory Mode
For factor use
0
0-1
Group 254 Fan Control Range Setting (Temp./Voltage)
Normal
Ceiling
HiLand-
Normal
HiLand-
Ceiling
0 High Fan Control Min Temp
Temp Senser Control Start/End Temp. at High
40
40
44
44
20-100
1 High Fan Control Max Temp
46
46
44
44
20-100
2 High Fan1 Min
Fan voltage value at High (unit: 0.1V)
75
75
135
135
0-255
3 High Fan1 Max
135
135
135
135
0-255
4 High Fan2 Min
85
85
130
130
0-255
5 High Fan2 Max
130
130
130
130
0-255
6 High Fan3 Min
75
80
80
85
0-255
7 High Fan3 Max
80
85
80
85
0-255
8 High Fan4 Min
9999
9999
-
9 High Fan4 Max
9999
9999
-
10 Normal Fan Control Min Temp
Temp Senser Control Start/End Tem.p at
Normal
40
40
44
44
20-100
11 Normal Fan Control Max Temp
46
46
44
44
20-100
12 Normal Fan1 Min
Fan voltage value at Normal (unit: 0.1V)
67
67
125
125
0-255
13 Normal Fan1 Max
125
125
125
125
0-255
14 Normal Fan2 Min
75
75
120
120
0-255
15 Normal Fan2 Max
120
120
120
120
0-255
16 Normal Fan3 Min
70
65
75
70
0-255
17 Normal Fan3 Max
75
70
75
70
0-255
18 Normal Fan4 Min
9999
9999
-
19 Normal Fan4 Max
9999
9999
-
20 Eco Fan Control Min Temp
Temp Senser Control Start/End Tem.p at Eco
38
38
44
44
20-100
21 Eco Fan Control Max Temp
44
44
44
44
20-100
22 Eco Fan1 Min
Fan voltage value at Eco (unit: 0.1V)
57
57
115
115
0-255
23 Eco Fan1 Max
115
115
115
115
0-255
24 Eco Fan2 Min
70
70
110
110
0-255
25 Eco Fan2 Max
110
110
110
110
0-255
26 Eco Fan3 Min
55
55
55
55
0-255
27 Eco Fan3 Max
55
55
55
55
0-255
28 Eco Fan4 Min
9999
9999
-
29 Eco Fan4 Max
9999
9999
-
Group 255 Fan Start/Cooling Setting
0 Fan1 Initial Volt
Fan Start Voltage (0.1V)
70
0-255
1 Fan2 Initial Volt
70
0-255
2 Fan3 Initial Volt
70
0-255
3 Not used
9999
-
4 Fan1 Cooling Speed
Fan Voltage at Power Off (0.1V)
130
0-255
5 Fan2 Cooling Speed
130
0-255
6 Fan3
Cooling Speed
130
0-255
7 Not used
9999
-
8 Cooling Time L1
Cooling Time stting at Fan Mode L1 (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
2
1-15
9 Cooling Time L2
Cooling Time stting at Fan Mode L2 (x 30 sec)
1: 30, 3: 90, 15: 450 sec.
3
1-15
10 Temp Error Cooling Time
Cooling Time setting at Temp Erro (x 30 sec)
3
1-15
11 OnStart Cooling Start Threshold
38
0-100
12 After shutdown cooling
Cooling after shutdown (0: No, 1: Yes)
1
0-1
Group 256 Fan Lamp Voltage Down Setting
0 Lamp Voltage
Current Lamp Voltage (0.1V)(Read only)
-
0-255
1 Lamp Vol Threshold
Threshold to judge Lamp Voltage Down ( V×
10)
30-90
Summary of Contents for PLC-XU101
Page 59: ... 59 IC Block Diagrams BA7078 Sync Separator IC5301 AN5870 Signal Switch IC5201 ...
Page 60: ... 60 IC Block Diagrams FA5502 P F Control IC601 FA7711 DC DC Converter IC5801 ...
Page 63: ... 63 IC Block Diagrams LM4889 Audio Output IC5031 M62334 DAC IC3501 ...
Page 64: ... 64 IC Block Diagrams NJW1141 Audio Control IC5001 PW190 Scaler IC301 ...
Page 65: ... 65 IC Block Diagrams STR Z2156 Power OSC IC651 ...
Page 94: ... KL6AC Jun 2007 DC 350 Printed in Japan SANYO Electric Co Ltd ...