PLC-XTC50AL Expand Serial Command Functional Specifications
49/76
9.4.11 CR_NZRED Command
Command
“CR_NZRED” [CR]
Details
Get Noise Reduction setting status
Response
Acceptable
“000_%1” [CR]
%1
“OFF” ------ Noise Reduction OFF
“L1” -------- Noise Reduction L1
“L2” -------- Noise Reduction L2
Unacceptable
“?” [CR]
9.4.12 CR_PROGV Command
Command
“CR_PROGV” [CR]
Details
Get Progressive scan setting status
Response
Acceptable
“000_%1” [CR]
%1
“OFF” --------------- Progressive scan OFF
“L1” ----------------- Progressive Mode L1 (for moving image)
“L2” ----------------- Progressive Mode L2 (for still image)
“FILM” -------------- Progressive Model FILM
Unacceptable
“?” [CR]
9.4.13 CR_IMAGE Command
Command “CR_IMAGE” [CR]
Details
Get image setting status
Response
Acceptable
“000_%1” [CR]
%1
“DYNAMIC” --------------------------------------- Dynamic
“STAND” ------------------------------------------- Standard
“REAL” --------------------------------------------- Real
“CINEMA” ----------------------------------------- Cinema
“CUSTOM1”~”CUSTOM4” -------------------- Image1~4
Unacceptable
“Error Code”[CR] ---- When the command is invalid due to
condition such as Input source
“?”[CR] -------------------- When unclear command is received
9.4.14 CR_IMGGMD Command
Command
“CR_IMGGMD” [CR]
Details
Get setting status of Dynamic/Standard/Real/Cinema in Image Gamma
Response
Acceptable
“000_%1” [CR]
%1
“DYN” ------------ Dynamic
“STD” ------------ Standard
“REL” ------------ Real
“CNM” ------------ Cinema
Unacceptable
“?” [CR]