PLC-XTC50AL Expand Serial Command Functional Specifications
40/76
8.10.9 CF_STANDBYMODE Command
Command “CF_STANDBYMODE_%1”[CR]
%1
“ECO” ---------------------- Less standby electricity
“NORMAL” --------------- Normal standby electricity (Selecting
NETWORK)
Details
Switch Standby Mode setting.
This command is available in normal Power ON status.
Response
Acceptable
“000”[CR]
Unacceptable “Error Code”[CR]
8.10.10 CF_P-MANE Command
Command “CF_P-MANE_%1” [CR]
%1
“OFF” ---------------------------------- Set Power Management to Off
“READY” ----------------------------- Set Power Management to Ready
“SHUTDOWN” --------------------- Set Power Management to Shut Down mode
“UP” ----------------------- Switch forward (Off
→
Ready
→
Shut down
→
Off)
“DN” ---------------------- Switch backward (Off
→
Shut down
→
Ready
→
Off)
Details
Set/Cancel Power Management
(Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.10.11 CF_P-MANETIME Command
Command “CF_P-MANETIME_%1” [CR]
%1
“01” - ”30” ----------------------- Directly specify setting time by the minute
“UP” -------------- Increment value by 1 (Switched in 01
→
02
→
---
→
30
→
01 order)
“DN” -------------- Decrement value by 1(Switched in 30
→
29
→
---
→
01
→
30 order)
Details
Set time of Power Management time (Available only in the normal Power ON
status)
The status set by this command is stored in EEPROM and setting remains
effective even after the power is turned to ALL OFF status.
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]
8.10.12 CF_ON-STA Command
Command “CF_ON-STA_%1” [CR]
%1
“ON” --------------------------- Set Power On Start to ON.
“OFF” ------------------------- Set Power On Start to OFF.
“UP” ---------- Toggle between ON and OFF.(On
→
Off
→
On
→
- - -)
“DN” --------- Toggle between ON and OFF.(On
→
Off
→
On
→
- - -)
*”UP” and “DN” are exactly same operation.
Details
Set/Cancel Power ON Start (Available only in the normal Power ON status)
The status set by this command is stored in EEPROM and setting value remains
effective even after the power is turned to ALL OFF status.
Response
Acceptable
“000” [CR]
Unacceptable
“Error Code” [CR]