PLC-XTC50AL Expand Serial Command Functional Specifications
74/76
9.12 Other Status Read Commands
9.12.1 CR_STATUS Command
COMMAND
“CR_STATUS” [CR]
Detail
Get operating status of Projector
Same as “CR0” in basic command except error code follows it.
Response
Acceptable
“000_%1” [CR]
%1
“00” = Power ON
“80” = Standby
“40” = Countdown in process
“20” = Cooling Down in process
“10” = Power Failure
“28” = Cooling Down in process due to abnormal temperature
“88” =Standby after Cooling Down due to abnormal
temperature
“24” = Power Save/Cooling Down in process
“04” = Power Save
“21” = Cooling Down in process after turned Off due to lamp
failure
“81”
=
Standby after Cooling Down due to lamp failure
“2C” = Cooling Down in process after Power Off due to
Shutter management
“8C” = Standby after Cooling Down due to
Shutter management
Unacceptable
“Error Code” [CR]
9.12.2 CR_SIGNAL Command
Command
“CR_SIGNAL” [CR]
Details
Get status whether there is any signal or not.
Response
Acceptable
“000_%1” [CR]
%1
“ON” -------------------------- There is signal
“OFF” ------------------------- There is no signal
Unacceptable “?” [CR]
9.12.3 CR_VMUTE Command
Command
“CR_VMUTE” [CR]
Details
Get setting status of Shutter.
Response
Acceptable
“000_%1” [CR]
%1
“ON” ---------- Video mute is ON(Shutter close)
“OFF” --------- Video mute is OFF(Shutter open)
Unacceptable “?” [CR]
9.12.4 CR_FREEZE Command
Command
“CR_FREEZE” [CR]
Details
Get setting status of Freeze.
Response
Acceptable
“000_%1” [CR]
%1
“ON” --------------------- Freeze is ON
“OFF” -------------------- Freeze is OFF
Unacceptable “?” [CR]