PDG-DXL2000 Expand Serial Command Functional Specifications
59/72
9.9 Lamp Status Read Command
9.9.1 CR_LAMPREPL Command
Command “CR_LAMPREPL”[CR]
Details
Get information of Lamp Replacement time
Acceptable
“000_%1”[CR]
%1
“1Y” -------------------------- Over lamp replacement time
“1N” -------------------------- Within lamp replacement time
“1” means the number of lamps.
(1 lamp model
→
“1”)
“Y”/”N” means if it has reached its replacement time or not.
e.g. “1Y” -----------projector is 1 lamp model and Lamp is over its
replacement time
Response
Unacceptable “Error code”[CR]
9.9.2 CR_LAMPH Command
Command “CR_LAMPH”[CR]
Details
Get total running time of lamp by hour (h)
*Actual running time, not corresponding value
Acceptable
“000_%1”[CR]
%1
“00000”~“99999”
Response
Unacceptable “Error code”[CR]
9.9.3 CR_LAMPCORRESPH Command
Command “CR_LAMPCORRESPH”[CR]
Details
Get total running time of lamp by hour (h)
* Corresponding value, not actual running time
Acceptable
“000_%1”[CR]
%1
“00000”~“99999”
Response
Unacceptable Error code”[CR]
9.9.4 CR_LAMPMODE Command
Command “CR_LAMPMODE”[CR]
Details
Get setting status of Lamp Mode
Acceptable
“000_%1”[CR]
%1
“NORMAL” -------------- Lamp Mode is Normal
“ECO” -------------------- Lamp Mode is Eco
Response
Unacceptable “Error code”[CR]