PDG-DXL2000 Expand Serial Command Functional Specifications
39/72
8.10.16 CF_TERMINAL Command
Command “CF_TERMINAL_%1”[CR]
%1
“COMPUTER” ----------------Set Input mode
“MONITOR” ------------------- Set Monitor Out mode
Details
Set Terminal setup. This command is available in normal Power ON status.
Terminal means Computer 2 in this model.
Acceptable
“000”[CR]
Response
Unacceptable
“Error Code”[CR]
When Input is Computer 2, the projector returns “101” and the
command is not executed.
8.10.17
CF_STANDBYMODE Command
Command “CF_STANDBYMODE_%1”[CR]
%1
“ECO” ---------------------- Less standby electricity
“NORMAL” --------------- Normal standby electricity
Details
Switch Standby Mode setting.
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.18 CF_P-MANE Command
Command “CF_P
−
MANE_%1”[CR]
%1
“OFF” --------------------------------- Set Power Management to OFF
“READY” ----------------------------- Set Power Management to Ready
“SHUTDOWN” --------------------- Set Power Management to Shut Down mode
“UP” ------------------------------ The same operation as pressing Up key or Left key
“DN” ------------------------------The same operation as pressing Down key or Right
key
Details
Set/Cancel Power Management
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response
Unacceptable “Error Code”[CR]
8.10.19 CF_P-MANETIME Command
Command “CF_P-MANETIME_%1”[CR]
%1
“01” ~ ”30” ----------------------- Directly select setting time by the minute
“UP” ------------------------------- Plus one minute (01
→
02
→
・・・
→
30
→
01)
“DN” ------------------------------- Minus one minute(30
→
29
→
・・・
→
01
→
30)
Details
Set Power Management time
The status set by this command is stored in EEPROM and its setting is effective
after ALL is OFF
This command is available in normal Power ON status.
Acceptable
“000”[CR]
Response