background image

PDG-DXL2000    Expand Serial Command Functional Specifications 

                                                                                   

                                                                               

49/72 

9.4.11  CR_NZRED Command 

Command  “CR_NZRED”[CR] 

Details 

Get setting status of Noise Reduction   

Acceptable 

“000_%1”[CR] 

%1 

“L1” -------- Noise Reduction for moving image 
“L2” -------- Noise Reduction for still image 
“OFF” ----- Noise Reduction is OFF 

Response 

Unacceptable  “Error code”[CR] 

 

9.4.12  CR_PROGV Command 

Command  “CR_PROGV”[CR] 

Details 

Get setting status of Progressive scan 

Acceptable 

“000_%a”[CR] 

%a 

“L1” ----------------- Progressive Mode L1 is selected 
“L2” ----------------- Progressive Mode L2 is selected 
“FILM” -------------- Progressive Model FILM is selected 
“OFF” --------------- Progressive scan is disabled 

Response 

Unacceptable  “Error code”[CR] 

 

9.4.13  CR_IMAGE Command 

Command  “CR_IMAGE”[CR] 

Details 

Get image setting status 
Required  data  “CUSTOM1” to “CUSTOM4”  is  the  same as “Image1”  to “Image4” 
displayed when selecting IMAGE on OSD menu 

Acceptable 

“000_%a”[CR] 

%a 

“DYNAMIC” --------------------------------------- Dynamic 
“STAND” ------------------------------------------- Standard 
“REAL” --------------------------------------------- Real 
“CINEMA” ----------------------------------------- Cinema 
“CUSTOM1”~”CUSTOM4” -------------------- Image1~4 

Response 

Unacceptable  “Error Code”[CR] 

 

9.4.14  CR_IMGGMD Command 

Command  "CR_IMGGMD”[CR] 

Details 

Get Image Gamma setting status 

Acceptable 

“000_%a”[CR] 

%a 

“DYN” ------------ Dynamic 
“STD” ------------ Standard   
“REL” ------------ Real   
“CNM” ----------- Cinema     

Response 

Unacceptable  “Error code”[CR]   

 

Summary of Contents for PDG-DXL2000 - 2000 Lumens

Page 1: ...EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PDG DXL2000 Ver 1 00 SANYO Electric Co Ltd DS Company Projector Division ...

Page 2: ... Table 12 6 1 Image Status Read Command Table 12 6 2 PC Adjust Status Read Command Table 12 6 3 Video Status Read Command Table 12 6 4 Input Status Read Command Table 12 6 5 Screen Status Read Command Table 13 6 6 Lamp Status Read Command Table 13 6 7 Sound Status Read Command Table 13 6 8 Setting Status Read Command Table 13 6 9 Other Status Read Command 14 7 Error Code Table 15 8 Functional Exec...

Page 3: ...nd 24 8 6 3 CF_INPUT1 Command 25 8 6 4 CF_INPUT2 Command 25 8 6 5 CF_INPUT3 Command 25 8 6 6 CF_INPUT4 Command 25 8 6 7 CF_INPUT5 Command 25 8 6 8 CF_INPUT_ 1_ 2 Command 26 8 6 9 CF_SYSTEM Command 26 8 7 Screen Control Command 27 8 7 1 CF_SCREEN Command 27 8 7 2 CF_DZCENT Command 27 8 7 3 CF_KEYSTONE Command 28 8 7 4 CF_KYSTNMODE Command 28 8 7 5 CF_VSCALE Command 28 8 7 6 CF_VPOS Command 29 8 7 7...

Page 4: ... CF_HDMI SOUND Command 38 8 10 16 CF_TERMINAL Command 39 8 10 17 CF_STANDBYMODE Command 39 8 10 18 CF_P MANE Command 39 8 10 19 CF_P MANETIME Command 39 8 10 20 CF_ON STA Command 40 8 10 21 CF_CCAPTIONDISP Command 40 8 10 22 CF_CCAPTIONCOLOR Command 40 8 10 23 CF_RCODE Command 41 8 10 24 CF_KEYDIS Command 41 8 10 25 CF_PJPINCODE Command 41 8 10 26 CF_FANMODE Command 42 8 10 27 CF_FANCONTROL Comman...

Page 5: ...nd 49 9 4 14 CR_IMGGMD Command 49 9 5 PC Adjust Status Read Command 50 9 5 1 CR_FSYNC Command 50 9 5 2 CR_TDOTS Command 50 9 5 3 CR_CLAMP Command 50 9 5 4 CR_H POS Command 50 9 5 5 CR_V POS Command 50 9 5 6 CR_PCSTORE Command 51 9 6 Video Status Read Command 52 9 6 1 CR_SERSYS Command 52 9 7 Input Status Read Command 53 9 7 1 CR_INPUT Command 53 9 7 2 CR_SOURCE Command 53 9 7 3 CR_SRCINP1 Command ...

Page 6: ...R_VOLUME Command 61 9 10 2 CR_MUTE Command 61 9 11 Setting Status Read Command 62 9 11 1 CR_LANG Command 62 9 11 2 CR_AUTOSETUPPCADJ Command 62 9 11 3 CR_INPUTSEARCH Command 62 9 11 4 CR_3DSET Command 63 9 11 5 CR_3DSYNC Command 63 9 11 6 CR_3DSIDE2D Command 63 9 11 7 CR_3DPHASE Command 63 9 11 8 CR_ ZOOM Command 63 9 11 9 CR_BACKGND Command 64 9 11 10 CR_DISP Command 64 9 11 11 CR_LOGO Command 64...

Page 7: ...d 67 9 11 27 CR_FANCONTROL Command 67 9 11 28 CR_FILH Command 67 9 11 29 CR_FILREPL Command 68 9 11 30 CR_FILTIMER Command 68 9 12 Other Status Read Command 69 9 12 1 CR_STATUS Command 69 9 12 2 CR_SIGNAL Command 69 9 12 3 CR_VMUTE Command 69 9 12 4 CR_FREEZE Command 69 9 12 5 CR_ PTIMER Command 70 9 12 6 CR_TEMPWARN Command 70 9 12 7 CR_TEMP Command 71 9 12 8 CR_TEMPFAIL Command 72 9 12 9 CR_ SER...

Page 8: ...mands are defined as Expand Serial Commands 2 Serial Interface Specification 2 1 Transfer Specification Item Specification Synchronous System Asynchronous Transmission Speed 9600 19200 Data Length 8 bit Parity N A Stop Bit 1 Flow Control N A Note1 Transmission Speed initial setting value is 19200 Note2 Transmission Speed can be changed in service mode 2 2 Connection Dedicated serial cable must be ...

Page 9: ...r CF_BRIGHT_032 CR Next Command Projector PC 000 CR Response A few ms 5s When a computer sends next command before receiving a response the projector may not operate properly except when there is no response for more than 5 seconds 5 It takes about 5 seconds for internal initialization after plugging in AC power During this time commands cannot be processed Do not issue any command 4 Name Definiti...

Page 10: ...t 5 2 PC Adjust Control Command Table Execute command Item CF_FSYNC_ 1 CR Set Fine Sync value CF_TDOTS_ 1 CR Set Total Dots value CF_CLAMP_ 1 CR Set Clamp Value CF_H POS_ 1 CR Set Horizontal Position value CF_V POS_ 1 CR Set Vertical Position value CF_PCSTORE_ 1 CR Store the setting value of PC Adjust menu to Mode 1 10 CF_PCMODEFREE_ 1 CR Delete the registered value in Mode 1 10 and return it to F...

Page 11: ...etup CF_INPUTSEARCH_ 1 CR Set Input search function CF_AUTOSETUP_ 1 CR Execute Auto Setup CF_3DSET_ 1 CR Set 3D function CF_3DSYNC_ 1 CR Set 3D Sync CF_3DSIDE2D_ 1 CR Set 3D 2D CF_3DPHASE_ 1 CR Set 3D Phase CF_ZOOM_ 1 CR Select Zoom store mode CF_BACKGND_ 1 CR Set screen mode for the case of no signal CF_DISP_ 1 CR Set Display function CF_LOGO_ 1_ 2 CR Set Logo function CF_HDMISETUP_ 1 CR Set Imag...

Page 12: ...5 8 Other Command Table Execute command Item CF_KEYEMU_ 1 CR Behave the same as corresponding key of the projector remote control CF_MENU_ 1 CR Switch ON OFF of each Menu CF_POWER_ 1 CR Switch ON OFF of Power CF_FREEZE _ 1 CR Set Freeze function CF_VMUTE _ 1 CR Set No show function CF_PTIMER_ 1 CR Set P Timer function ...

Page 13: ...NC CR Get setting value of Fine Sync CR_TDOTS CR Get setting value of Total Dots CR_CLAMP CR Get setting value of Clamp CR_H POS CR Get setting value of Horizontal Position CR_V POS CR Get setting value of Vertical Position CR_PCSTORE CR Get Free or Stored status for PC Adj Mode 1 10 6 3 Video Status Read Command Table Status read command Item CR_SERSYS CR Get selected current signal When in Auto ...

Page 14: ... Get selected language CR_AUTOSETUPPCADJ Get setting status of Auto PC in Auto setup CR_INPUTSEARCH CR Get setting status of Input search CR_3DSET CR Get setting status of 3D function CR_3DSYNC CR Get setting status of 3D Sync CR_3DSIDE2D CR Get setting status of 3D 2D CR_3DPHASE CR Get the value of 3D Phase CR_ZOOM CR Get setting status of Zoom store mode CR_BACKGND CR Get setting status screen m...

Page 15: ... Command Status read command Item CR_STATUS CR Get setting status of Projector behavior CR_SIGNAL CR Get Signal Status if there is a signal or not CR_VMUTE CR Get setting status of No Show CR_FREEZE CR Get setting status of Freeze CR_PTIMER CR Get operation status of P timer CR_TEMPWARN CR Get if temperature is close to abnormal temperature CR_TEMP CR Get current temperature status CR_TEMPFAIL CR ...

Page 16: ...ving signal related commands while no signal is entered 102 Selected value is out of range Not reflected 103 Command mismatched to Hardware command for Optional function which is not installed 201 When reached upper or lower limit of increasing or decreasing data 301 Command cannot be executed during capturing display 302 Command cannot be executed during Auto setup operation 402 Command cannot be...

Page 17: ...able 8 3 Operation Requirements 1 Functional Execution Command is limited when the projector status is as below However Status Read Command is effective even under these conditions Projector Status Available Functional Execution Command In Standby status C00 POWER ON only Countdown in process C00 POWER ON Terminates Countdown C01 POWER OFF C02 POWER OFF Terminates Countdown Cooling down in process...

Page 18: ...s to original setting The value is held in Suspend mode This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 4 3 CF_COLOR Command Command CF_COLOR_ 1 CR 1 000 063 Directly select Color setting value UP Current Color setting value 1 DN Current Color setting value 1 Details Set Color value of user control The value set by this command will not b...

Page 19: ...mma value of user control The value set by this command will not be saved to projector Therefore when turning into Standby status or ALL is OFF the value returns to original setting The value is held in Suspend mode This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 4 7 CF_WBAL Command Command CF_WBAL 1_ 2 CR 1 R Red G Green B Blue 2 000 063...

Page 20: ...scan The value set by this command will not be saved to projector Therefore when turning into Standby status or ALL is OFF the value returns to original setting The value is held in Suspend mode This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 4 10 CF_NZRED Command Command CF_NZRED_ 1 CR 1 OFF Cancel Noise Reduction L1 Noise Reduction for ...

Page 21: ...age4 displayed when selecting Image on OSD menu The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 4 12 CF_IMAGEADJ Command Command CF_IMAGEADJ_ 1 CR 1 RST Reset Image adjustment STR1 Store current Image adjustment to Image 1 STR2 Store curre...

Page 22: ... maximum value which is not over 150MHz UP Current Total Dots setting value 1 DN Current Total Dots setting value 1 Details Set Total Dots of PC signal The value set by this command will not be saved to projector Therefore when turning into Standby status or ALL is OFF the value returns to original setting This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable ...

Page 23: ...Details Set Vertical Position value of PC signal The value set by this command will not be saved to projector Therefore when turning into Standby status or ALL is OFF the value returns to original setting This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable 101 CR When Input source is Video system 8 5 6 CF_PCSTORE Command Command CF_PCSTORE_ 1 CR 1 MODE1 Stor...

Page 24: ...ODE5 Set Mode5 to Free status MODE6 Set Mode6 to Free status MODE7 Set Mode7 to Free status MODE8 Set Mode8 to Free status MODE9 Set Mode9 to Free status MODE10 Set Mode10 to Free status Details Delete the registered data in Mode1 Mode5 and turns it to Free status This command operates the same as turning Mode1 Mode5 to Free in PC Adjust Menu This command is available in normal Power ON status Acc...

Page 25: ...Input is Computer 1 ANALOG Select Analog Input YPBPR Select Component Input SCART Select Scart Input UP The same operation as pressing Up key or Left key DN The same operation as pressing Down key or Right key Input is Computer 2 ANALOG Select Analog Input UP DN Projector accepts parameter UP DN but no operation is made Input is HDMI HDMI Select HDMI Input UP DN Projector accepts parameter UP DN b...

Page 26: ... out is selected in Terminal menu Acceptable 000 CR Response Unacceptable Error Code CR 8 6 5 CF_INPUT3 Command Command CF_INPUT3_ 1_ CR 1 HDMI Select HDMI Details Select HDMI Input and source specified in 1 at once This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 6 6 CF_INPUT4 Command Command CF_INPUT4 _ 1 CR 1 VIDEO Select Composite vide...

Page 27: ...ied by 1 and also Source specified in 2 This command is available in normal Power ON status Projector returns 101 by selecting Computer 2 while Monitor out is selected in Terminal menu Acceptable 000 CR Response Unacceptable Error Code CR 8 6 9 CF_SYSTEM Command Command CF_SYSTEM_ 1 CR 1 Input is Computer VGA1 Select VGA1 XGA1 Select XGA1 WXGA3 Select WXGA3 1080I Select 1080I 720P Select 720P 575P...

Page 28: ...s pressing Up key or Left key DN The same operation as pressing Down key or Right key 1 AV PC Common RST Reset screen adjustment Details Select image size on screen When Input specified by 1 is inappropriate for selected Input the projector returns 101 CR and the command is not executed DZOOM UP and DZOOM DN start effecting from the first command This command is available in normal Power ON status...

Page 29: ...ching 1 step to correction limit and FDN FUP is received The command is not executed 8 7 4 CF_KYSTNMODE Command Command CF_KYSTNMODE_ 1 CR 1 STR Set Keystone store mode to Store RST Set Keystone store mode to Reset Details Set Keystone store mode This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 7 5 CF_VSCALE Command Command CF_VSCALE_ 1 CR...

Page 30: ...2 When there is no Input projector returns 101 and the command does not execute Acceptable 000 CR Response Unacceptable Error Code CR 8 7 7 CF_HSCALE Command Command CF_HSCALE_ 1 CR 1 032 32 031 31 002 2 001 1 000 0 01 1 02 2 31 31 32 32 UP Horizontal Scale setting value 1 DN Horizontal Scale setting value 1 Details Set Horizontal Scale This command is available in normal Power ON status Note1 Scr...

Page 31: ...able Error Code CR 8 7 9 CF_CEIL Command Command CF_CEIL_ 1 CR 1 ON Set Ceiling to ON OFF Set Ceiling to OFF Details Set Cancel Ceiling setting The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 7 10 CF_REAR Command Command CF_REAR_ 1 CR 1 ON...

Page 32: ...Yellow GREEN Select Green BLACKBOARD Select Blackboard Details Select Color of Colorboard mode Image mode is automatically switched to Colorboard mode by receiving this command The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR ...

Page 33: ...Code CR 8 8 2 CF_LAMPMODE Command Command CF_LAMPMODE_ 1 CR 1 NORMAL Set lamp to Normal mode status ECO Set lamp to 3L mode status UP The same operation as pressing Up key or Left key DN The same operation as pressing Down key or Right key Details Select Lamp Mode The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in norma...

Page 34: ...and RC and directly select Volume setting value When setting Volume value the Sound Mute ON status is canceled just like RC operation The value set by this command is stored in Projector This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 9 2 CF_MUTE Command Command CF_MUTE_ 1 CR 1 ON Set Sound Mute to ON OFF Set Sound Mute to OFF Details Con...

Page 35: ...edChinese HON Select Traditional Chinese KOR Select Korean JPN Select Japanese THA Select Thai Details Set language for OSD The status set by this command is stored in EEPROM and its setting is effective after ALL is OFF This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 10 2 CF_MENUPOSITION Command Command CF_MENUPOSITION_ 1 CR 1 SET Move t...

Page 36: ...tored in EEPROM and its setting is effective after ALL is OFF This command is available in normal Power ON status Note It is unable to set both PC ADJ and Input search to OFF If projector receives Input search OFF command while Auto PC ADJ is OFF it returns error code 101 Acceptable 000 CR Response Unacceptable Error Code CR 8 10 5 CF_AUTOSETUP Command Command CF_AUTOSETUP_ 1 CR 1 START Execute Au...

Page 37: ...R Response Unacceptable Error Code CR 8 10 9 CF_3DPHASE Command Command CF_3DPHASE _ 1 CR 1 000 031 Directly select 3D phase setting value UP Current 3D Phase setting value 1 DN Current 3D phase setting value 1 Details Setup 3D phase setting value The status set by this command is stored in EEPROM and its setting is effective after ALL is OFF This command is available in normal Power ON status Acc...

Page 38: ...mains even after the power is turned to ALL OFF status When 1 USER is received error code 101 is returned in the case of Capture non practice Acceptable 000 CR Response Unacceptable Error Code CR 8 10 12 CF_DISP Command Command CF_DISP_ 1 CR 1 ON Select Display OFF Cancel Display CNTDWNOFF Count down OFF UP The same operation as pressing Up key or Left key DN The same operation as pressing Down ke...

Page 39: ... invalid Error Code Note Receiving correct LOGO PIN CODE while LOGO LOCK is in operation enables to change LOGO setting but it does not release LOGO LOCK LOGO LOCK continues Projector returns Error Code 101 by receiving USER in 2 when capture has not operated Acceptable 000 CR Response Unacceptable Error Code CR 8 10 14 CF_ HDMI SETUP Command Command CF_ HDMI SETUP _ 1 CR 1 NORMAL Select Normal mo...

Page 40: ... MANE Command Command CF_P MANE_ 1 CR 1 OFF Set Power Management to OFF READY Set Power Management to Ready SHUTDOWN Set Power Management to Shut Down mode UP The same operation as pressing Up key or Left key DN The same operation as pressing Down key or Right key Details Set Cancel Power Management The status set by this command is stored in EEPROM and its setting is effective after ALL is OFF Th...

Page 41: ...Details Select channel of Closed caption The status set with this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status Note Closed caption is available under conditions below Entered signal is appropriate Video NTSC signal of S video Acceptable 000 CR Response Unacceptable Error Code CR 8 10 22 CF_CCAPTIONCOLOR Command C...

Page 42: ...anel buttons only Disable RC Projector keys This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 10 25 CF_PJPINCODE Command Command CF_PJPINCODE_ 1 CR 1 0000 9999 Set PJ PIN CODE directly Details Set PJ PIN CODE to release PJ LOCK PIN CODE cannot be changed by this command When PJ LOCK is in operation PIN CODE is correct Command is valid Accep...

Page 43: ...Fan control to Off ON1 Set Fan control to On1 ON2 Set Fan control to On2 Details Set Fan control setting The status set by this command is stored in EEPROM and its setting is effective even after ALL is OFF This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 10 28CF_FILTIMER Command Command CF_FILTIMER_ 1 CR 1 2000 Set 2000 hours 3000 Set 300...

Page 44: ...unctional Specifications 43 72 8 10 30CF_FDEFAULT Command Command CF_FDEFAULT_ 1 CR 1 RST Details Set the value to Factory Default This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR ...

Page 45: ...de CR 8 11 2 CF_MENU Command Command CF_MENU_ 1 CR 1 ON Display OSD Menu OFF Cancel OSD menu Details Display Cancel On Screen Display Menu This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 11 3 CF_POWER Command Command CF_POWER_ 1 CR 1 ON Power ON projector OFF Power OFF Projector Note1 Countdown can be terminated by sending this command No...

Page 46: ...l Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 11 5 CF_VMUTE Command Command CF_VMUTE_ 1 CR 1 ON Set No show ON OFF Set No show OFF UP Switch setting On Off On DN Switch setting On Off On Note UP and DN behave the same Details Set Cancel No show setting This command is available in normal Power ON status Acceptable 000 CR Response Unacceptable Error Code CR 8 11 6 CF_PTI...

Page 47: ...equired data 000 1 CR 1 Required Data Character Line See Basic Status Read Command Table 3 When the received data cannot be decoded the projector returns CR 9 2 Transfer Example Get total dots of projector by Expand Commands PC PJ CR_TDOTS CR PC PJ 000_1344 CR 9 3 Operation Condition 1 Basically Status Read Commands should be always operated 2 Status Read Commands are invalid when Eco mode is sele...

Page 48: ...er control Acceptable 000_ a CR a 000 063 Response Unacceptable Error code CR 9 4 3 CR_COLOR Command Command CR_COLOR CR Details Get Color value of user control Acceptable 000_ a CR a 000 063 Response Unacceptable Error code CR 9 4 4 CR_TINT Command Command CR_TINT CR Details Get Tint value of user control Acceptable 000_ a CR a 000 063 Response Unacceptable Error code CR 9 4 5 CR_SHARP Command Co...

Page 49: ...trol Acceptable 000_ a CR a 000 063 Response Unacceptable Error code CR 9 4 8 CR_WBAL G Command Command CR_WBAL G CR Details Get White Balance Green value of user control Acceptable 000_ a CR a 000 063 Response Unacceptable Error code CR 9 4 9 CR_WBAL B Command Command CR_WBAL B CR Details Get White Balance Blue value of user control Acceptable 000_ a CR a 000 063 Response Unacceptable Error code ...

Page 50: ...ted L2 Progressive Mode L2 is selected FILM Progressive Model FILM is selected OFF Progressive scan is disabled Response Unacceptable Error code CR 9 4 13 CR_IMAGE Command Command CR_IMAGE CR Details Get image setting status Required data CUSTOM1 to CUSTOM4 is the same as Image1 to Image4 displayed when selecting IMAGE on OSD menu Acceptable 000_ a CR a DYNAMIC Dynamic STAND Standard REAL Real CIN...

Page 51: ...ximum value depends on input signal Response Unacceptable Error Code CR 9 5 3 CR_CLAMP Command Command CR_CLAMP CR Details Get Clamp value Acceptable 000_ a CR a 0001 nnnn nnnn depends on input signal Response Unacceptable Error Code CR 9 5 4 CR_H POS Command Command CR_H POS CR Details Get Horizontal Position value Acceptable 000_ a CR a 0000 nnnn nnnn Total Dots Display Dots Response Unacceptabl...

Page 52: ...us of MODE1 MODE10 for PC Adjust The data consists of 10 bytes and each byte indicates the status of MODE1 MODE10 respectively F Free S Stored Acceptable 000_ a CR Requested data FFFFFFFFFF All Free SFFFFFFFFF MODE1 is Stored others are Free FFFFFFFFFS MODE10 is Stored others are Free SSSSSSSSSS All Stored Response Unacceptable Error code CR ...

Page 53: ...al in Auto mode Only available for Video input N A when Input is computer Acceptable 000_ 1 CR Demand data 1080P60 1080p 60Hz 1080P50 1080p 50Hz 1080P30 1080p 30Hz 1080P25 1080p 25Hz 1080P24 1080p 24Hz 720P60 720p 720P50 720p 575P 575p 480P 480p 575I 575i includes Composite signal such as PAL 480I 480i includes Composite signal such as NTSC NO_SIGNAL There is no signal Response Unacceptable Error ...

Page 54: ...t Input is selected Response Unacceptable Error code CR 9 7 3 CR_SRCINP1 Command Command CR_SRCINP1 CR Details Get selected source of Input 1_CMP1 Acceptable 000_ 1 CR Request data ANALOG Analog Input is selected YPBPR YPBPR Input is selected SCART Scart Input is selected Response Unacceptable Error code CR 9 7 4 CR_SRCINP2 Command Command CR_SRCINP2 CR Details Get selected source of Input 2_CMP2 ...

Page 55: ...d source of Input 4_Video Acceptable 000_ 1 CR Request data VIDEO Composite Video Input is selected Response Unacceptable Error code CR 9 7 7 CR_SRCINP5 Command Command CR_SRCINP5 CR Details Get selected source of Input 5_S video Acceptable 000_ 1 CR Request data S VIDEO S Video Input is selected Response Unacceptable Error code CR ...

Page 56: ...I D XGA1 D XGA1 is selected D WXGA3 D WXGA3 is selected D 1080I D 1080i is selected D 720P D 720p is selected D 575P D 575p is selected D 480P D 480p is selected When there is no signal projector returns error code 101 CR Input is Y Pb Cb Pr Cr 1080i 1080i is selected 720p 720p is selected 575p 575p is selected 480p 480p is selected 575i 575i is selected 480i 480i is selected Projector returns sel...

Page 57: ...20P is selectable When there is no signal projector returns Error Code 101 When Input is Y Pb Cb Pr Cr Projector return Error Code 101 When Input is Video S Video Projector return Error Code 101 Response Unacceptable Error Code CR 9 7 10 CR_MODELIST Command Command CR_MODELIST CR Details Get selectable Mode titles Acceptable 000_ 1_ 2_ _ x CR 1 2 x Returns Error code 101 when Input is other than P...

Page 58: ... is selected FULL Full mode is selected WIDE Wide 16 9 mode is selected ZOOM Zoom mode is selected CUSTOM Custom size is selected Response Unacceptable Error Code CR 9 8 2 CR_ KYSTNMODE Command Command CR_KYSTNMODE CR Details Get setting status of Keystone Store Mode Acceptable 000_ a CR a STR Store mode is Store RST Store mode is Reset Response Unacceptable Error code CR 9 8 3 CR_VSCALE Command C...

Page 59: ...CEIL CR Details Get setting status of Ceiling Acceptable 000_ 1 CR 1 ON Ceiling ON is selected OFF Ceiling OFF is selected Response Unacceptable Error code CR 9 8 8 CR_ REAR Command Command CR_REAR CR Details Get setting status of Rear Acceptable 000_ 1 CR 1 ON Rear ON is selected OFF Rear OFF is selected Response Unacceptable Error code CR 9 8 9 CR_ COLBOARD Command Command CR_COLBOARD CR Details...

Page 60: ...nse Unacceptable Error code CR 9 9 2 CR_LAMPH Command Command CR_LAMPH CR Details Get total running time of lamp by hour h Actual running time not corresponding value Acceptable 000_ 1 CR 1 00000 99999 Response Unacceptable Error code CR 9 9 3 CR_LAMPCORRESPH Command Command CR_LAMPCORRESPH CR Details Get total running time of lamp by hour h Corresponding value not actual running time Acceptable 0...

Page 61: ...is ON O Lamp is OFF X Lamp failure e g 1I 1 Iamp model and Lamp is ON 2IO 2 lamps model and No 1 Lamp is ON and No 2Lamp is OFF 4IOXI 4 lamps model and No 1 No 4 lamps are ON No 2 lamp is OFF and No 3 model is failed Response Unacceptable Error Code CR 9 9 6 CR_PROJH Command Command CR_PROJH CR Details Get total running time of Projector by hour h Acceptable 000_ 1 CR 1 0000000 0099999 Response Un...

Page 62: ...ommand Command CR_VOLUME CR Details Get Volume value of user control Acceptable 000_ a CR a 000 063 Response Unacceptable Error code CR 9 10 2 CR_MUTE Command Command CR_MUTE CR Details Get sound mute setting status Acceptable 000_ a CR a ON Sound Mute is ON OFF Sound Mute is OFF Response Unacceptable Error code CR ...

Page 63: ...ilian Portuguese TUR Select Turkish ARA Select Arabic KAZ Select Kazak CHI Select SimpllifiedChinese HON Select Traditional Chinese KOR Select Korean JPN Select Japanese THA Select Thai Response Unacceptable Error code CR 9 11 2 CR_AUTOSETUPPCADJ Command Command CR_AUTOSETUPPCADJ CR Details Get Auto PC adj setting status in Auto setup Acceptable 000_ a CR a ON Auto PC ADJ in Auto setup is ON OFF A...

Page 64: ... selected 2 2 is selected Response Unacceptable Error Code CR 9 11 6 CR_3DSIDE2D Command Command CR_3DSIDE2D CR Details Get setting status of 3D 2D Acceptable 000_ a CR a ON On is selected OFF Off is selected Response Unacceptable Error Code CR 9 11 7 CR_3DPHASE Command Command CR_3DPHASE CR Details Get the value of 3D Phase Acceptable 000_ a CR a 000 031 Response Unacceptable Error Code CR 9 11 8...

Page 65: ...ode CR 9 11 11CR_LOGO Command Command CR_LOGO CR Details Get setting status of Logo Acceptable 000_ 1 CR 1 OFF Logo function is OFF DFLT Default Logo is selected USER User Logo is selected Response Unacceptable Error code CR 9 11 12 CR_HDMI SETUP Command Command CR_HDMI SETUP CR Details Get status of Image mode in HDMI setup Acceptable 000_ 1 CR 1 NORMAL Image mode is Normal ENHANCED Image mode is...

Page 66: ...e CR 9 11 16CR_P MANE Command Command CR_P MANE CR Details Get Power management setting status Acceptable 000_ a CR a OFF Power Management is OFF READY Power Management is Ready SHUTDOWN Power Management is set to Shut Down mode Response Unacceptable Error code CR 9 11 17 CR_P MANETIME Command Command CR_P MANETIME CR Details Get time to start Power Management Acceptable 000_ a CR a 001 030 1 minu...

Page 67: ...21 CR_RCODE Command Command CR_RCODE CR Details Get selected Remote Control Code Acceptable 000_ a CR a 001 Code1 is selected 002 Code2 is selected Response Unacceptable Error code CR 9 11 22 CR_SECURITY Command Command CR_SECURITY CR Details Get Security Mode setting status Acceptable 000_ 1 CR 1 ON PJ Lock setting on Menu is ON 1 or ON 2 OFF PJ Lock setting on Menu is OFF Response Unacceptable E...

Page 68: ...KMENU CR Details Get status of PJ Lock on Menu Acceptable 000_ 1 CR 1 ON1 PJ Lock status is On 1 ON2 PJ Lock status is On 2 OFF PJ Lock status is OFF Response Unacceptable Error Code CR 9 11 26 CR_FANMODE Command Command CR_FANMODE CR Details Get selected Fan mode Acceptable 000_ a CR a L1 Fan mode is L1 L2 Fan mode is L2 Response Unacceptable Error code CR 9 11 27 CR_FANCONTROL Command Command CR...

Page 69: ...ime Acceptable 000_ 1 CR 1 1Y Over filter replacement time 1N Within filter replacement time Response Unacceptable Error Code CR 9 11 30 CR_FILTIMER Command Command CR_FILTIMER CR Details Get setting time which filter warning OSD is displayed Acceptable 000_ 1 CR 1 2000 2000 hours 3000 3000 hours 4000 4000 hours OFF No OSD display Response Unacceptable Error Code CR ...

Page 70: ...saving 21 Cooling down due to Lamp failure 81 Stand by after Cooling down due to Lamp failure Response Unacceptable Error Code CR 9 12 2 CR_SIGNAL Command Command CR_SIGNAL CR Details Get Signal status if there is signal or not Acceptable 000_ a CR a ON Signal is found OFF There is no signal Response Unacceptable Error code CR 9 12 3 CR_VMUTE Command Command CR_VMUTE CR Details Get setting status ...

Page 71: ... 000_ a_ b_ c CR a b c a Sensor 1 status b Sensor 2 status c Sensor 3 status W Approach or reach abnormal temperature dangerous temperature S Far from abnormal temperature safe temperature N Sensor detects no abnormal temperature Example S_W_S CR means Sensor 1 detects safe temperature Sensor 2 detects abnormal temperature and Sensor 3 detects safe temperature Note When the temperature difference ...

Page 72: ...play Warning S Not close to abnormal temperature Temperature is low enough and safe N Applicable sensor does not detect abnormal temperature E Not able to return temperature data When several sensors are incorporated projector returns values continuously e g _31 5F__35 2S__38 0W CR A data of sensor 1 comes first and a data of sensor 2 follows after 1 space As described respectively in e g sensor 1...

Page 73: ...aracter means the sensor s status if it reaches abnormal temperature Exceeding critical temp F Temp is safe S Sensor detects no critical temp N The example shows that sensor 1 indicates 31 5 degrees and the temperature is abnormal When the temperature is safe all data are represented as 000S When the projector is reset 000S is set and every time abnormal temperature occurs it renews the data and r...

Reviews: